Literature DB >> 7055544

Intraocular lens power calculation for emmetropia: a clinical study.

J S Hillman.   

Abstract

A series of 50 eyes received an intraocular lens (IOL) of power calculated for emmetropia from data of axial length, corneal curvature, and postoperative anterior chamber depth by R. D. Binkhorst's formulae. The postoperative refraction results were compared with those of 100 control eyes which received +19 D standard power IOLs without calculation. The calculated group had postoperative refractions which were closer to emmetropia, and the difference was os statistical significance, with 92% within the +/- 1D range and 98% within the +/- 2 D range from emmetropia. The calculated predictions of postoperative refraction were of a useful level of accuracy. Consideration of the sources of error indicates that there is no justification for the use of IOLs in power steps of less than 1 D. The calculation of IOL power allows the surgeon to control the postoperative refraction and avoid unwanted ametropia.

Mesh:

Year:  1982        PMID: 7055544      PMCID: PMC1039712          DOI: 10.1136/bjo.66.1.53

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  6 in total

1.  Pitfalls in the determination of intraocular lens power without ultrasound.

Authors:  R D Binkhorst
Journal:  Ophthalmic Surg       Date:  1976

2.  Posterior chamber intraocular lens power calculation in 441 cases.

Authors:  W F Maloney; R P Kratz; T R Mazzocco; B Davidson
Journal:  J Am Intraocul Implant Soc       Date:  1979-10

3.  Determination of intraocular lens power: a comparison with and without ultrasound.

Authors:  M C Kraff; D R Sanders; H L Lieberman
Journal:  Ophthalmic Surg       Date:  1978-02

4.  The computer calculation of intraocular lens power. A clinical study.

Authors:  J S Hillman
Journal:  Trans Ophthalmol Soc U K       Date:  1980-04

5.  Clinical prediction versus ultrasound measurement of IOL power.

Authors:  C E Clevenger
Journal:  J Am Intraocul Implant Soc       Date:  1978-10

6.  Clinical evaluation of the DBR A-scan unit.

Authors:  G E Johns
Journal:  J Am Intraocul Implant Soc       Date:  1979-07
  6 in total
  2 in total

1.  Intraocular lens power calculation for planned ametropia: a clinical study.

Authors:  J S Hillman
Journal:  Br J Ophthalmol       Date:  1983-04       Impact factor: 4.638

Review 2.  Optimising biometry for best outcomes in cataract surgery.

Authors:  R Sheard
Journal:  Eye (Lond)       Date:  2013-12-06       Impact factor: 3.775

  2 in total