Literature DB >> 7012318

Distortion of ceramometal fixed partial dentures during the firing cycle.

D V Bridger, J I Nicholls.   

Abstract

1. Distortion does occur in the body of curved, long-span fixed partial denture frameworks during the porcelain firing cycle. 2. This distortion is a result of changes in the metal as well as the contraction of fired porcelain. 3. The greatest distortional changes occur during the degassing stage and the final glaze stage of the porcelain firing cycle. 4. Distortion incurred by the application and firing of the porcelain is reversible. When the porcelain is chemically removed from the framework, there is an elastic rebound. 5. Distortion is clinically important in that it may lead to detectable marginal openings. 6. The distortion pattern observed in the curved fixed partial denture is a closing of the posterior or lingual dimensions and labial movement in the anterior dimension. This indicates the effect of the contracting porcelain on the metal framework.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7012318     DOI: 10.1016/0022-3913(81)90036-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

2.  Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method.

Authors:  Rodrigo Tiossi; Hilmo Barreto Leite Falcão-Filho; Fábio Afrânio de Aguiar; Renata Cristina Silveira Rodrigues; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

3.  A comparative study of the effect of four consecutive firing cycles on the marginal fit of all: ceramic crown system and metal ceramic crown system.

Authors:  Ganesh B Bajaj
Journal:  J Indian Prosthodont Soc       Date:  2012-09-28

4.  X-Ray diffraction and scanning electron microscopy-energy dispersive spectroscopic analysis of ceramõmetal interface at different firing temperatures.

Authors:  Monika Saini; Suresh Chandra; Yashpal Singh; Bikramjit Basu; Arvind Tripathi
Journal:  Contemp Clin Dent       Date:  2010-07

5.  Comparative assessment of marginal accuracy of grade II titanium and Ni-Cr alloy before and after ceramic firing: An in vitro study.

Authors:  Abhijit Patil; Kishan Singh; Sukant Sahoo; Suraj Suvarna; Prince Kumar; Anupam Singh
Journal:  Eur J Dent       Date:  2013-07

6.  Marginal Adaptation of Implant Prostheses Fabricated by Different Materials in Excessive Crown Height Space before and after Veneering.

Authors:  Safoura Ghodsi; Marzieh Alikhasi; Majid Sahebi; Vahideh Nazari
Journal:  Front Dent       Date:  2021-07-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.