Literature DB >> 6867102

The validity of Monte Carlo simulation in studies of scattered radiation in diagnostic radiology.

H P Chan, K Doi.   

Abstract

A computer program using Monte Carlo methods has been developed for the simulation of photon scattering in tissue-equivalent phantoms for incident x-rays in the diagnostic energy range. The study verified that the sampling schemes used in the program can produce random samples according to the theoretical probability distribution functions which describe the photon-scattering process. The Monte Carlo program was applied to determinations of the scatter fractions and edge responses for various phantom sizes, X-ray energies, and recording systems. These quantities were also measured experimentally under comparable imaging conditions. Excellent agreement was obtained between the predicted and experimental results. This investigation established the validity of our Monte Carlo calculations for studies of the physical characteristics of scattered radiation in diagnostic radiology.

Entities:  

Mesh:

Year:  1983        PMID: 6867102     DOI: 10.1088/0031-9155/28/2/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Comparison of anti-scatter grids for digital imaging with use of a direct-conversion flat-panel detector.

Authors:  Masayoshi Mizuta; Shigeru Sanada; Hiroyuki Akazawa; Toshifumi Kasai; Shuji Abe; Yasuhiro Ikeno; Shigeki Mitou
Journal:  Radiol Phys Technol       Date:  2011-10-05

2.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

3.  Estimating scatter from sparsely measured primary signal.

Authors:  Gongting Wu; Christina R Inscoe; Jabari Calliste; Jing Shan; Yueh Z Lee; Otto Zhou; Jianping Lu
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-29

4.  Simulation of scattered radiation during intraoperative imaging in a virtual reality learning environment.

Authors:  Matthias Süncksen; Oliver Johannes Bott; Klaus Dresing; Michael Teistler
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-03-04       Impact factor: 2.924

5.  Experimental verification of reverse order of diagnostic X-ray beam quality in voltage-ripple dependence.

Authors:  M Matsumoto; H Kubota; Y Ozaki; H Kanamori
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

6.  Experimental separation of diagnostic X-ray spectra into scatter and primary components.

Authors:  H Kubota; Y Ozaki; M Matsumoto; H Kanamori
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

7.  Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy.

Authors:  Stephen Brunner; Brian E Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2011-01-21       Impact factor: 3.609

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.