Literature DB >> 686050

Diagnosis of intrauterine growth retardation by a simple clinical method: measurement of uterine height.

J M Belizán, J Villar, J C Nardin, J Malamud, L S De Vicurna.   

Abstract

Generally there is a tendency to underrate the value of uterine height in the diagnosis of intrauterine growth retardation (IUGR). This fact is probably due to the lack of standard normal values for this measurement. In a group of 298 healthy pregnant women, the 10th, 50th, and 90th percentile were calculated by week of amenorrhea. Uterine height was measured with a nonelastic measuring tape, from the symphysis pubis to the fundus uteri. With the use of these standard values the predictive value of the method was established. Of 44 neonates with low birth weight for gestational age, 38 had a uterine height below the 10th percentile (sensitivity 86%). Six cases of IUGR were not diagnosed by this method. Of 95 neonates with adequate birth weight, 85 had uterine values above the 10th percentile (specificity 90%). Ten (10%) of these were predicted as low birth weight but were born with adequate weight. The uterine height measurement is shown to be a very good method for detecting IUGR. It can be used as a screening test to detect impairment in fetal growth and to make early referral of those pregnancies.

Entities:  

Mesh:

Year:  1978        PMID: 686050     DOI: 10.1016/0002-9378(78)90824-4

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  27 in total

Review 1.  Symphysis-fundal height measurement in pregnancy.

Authors:  J P Neilson
Journal:  Cochrane Database Syst Rev       Date:  2000

2.  Dating gestational age by last menstrual period, symphysis-fundal height, and ultrasound in urban Pakistan.

Authors:  Imtiaz Jehan; Shahida Zaidi; Sameera Rizvi; Naushaba Mobeen; Elizabeth M McClure; Breda Munoz; Omrana Pasha; Linda L Wright; Robert L Goldenberg
Journal:  Int J Gynaecol Obstet       Date:  2010-09       Impact factor: 3.561

3.  Clinical assessment of gestational age: a comparison of two methods.

Authors:  D Faustin; L Gutierrez; J Gintautas; R J Calame
Journal:  J Natl Med Assoc       Date:  1991-05       Impact factor: 1.798

4.  The prenatal assessment of fetal health.

Authors:  J Parboosingh; J Mousseau; J Deacon
Journal:  Can Fam Physician       Date:  1979-06       Impact factor: 3.275

5.  Can fundal height predict birth weight or twins?

Authors:  J L Reynolds; A Kettner; M Burnett; M Cheang
Journal:  Can Fam Physician       Date:  1986-01       Impact factor: 3.275

6.  Symphysis-fundus measurements in screening for small-for-dates infants: a community based study in Gloucestershire.

Authors:  J M Stuart; T J Healy; M Sutton; G R Swingler
Journal:  J R Coll Gen Pract       Date:  1989-02

7.  Maternal leucocyte zinc deficiency at start of third trimester as a predictor of fetal growth retardation.

Authors:  J L Wells; D K James; R Luxton; C A Pennock
Journal:  Br Med J (Clin Res Ed)       Date:  1987-04-25

8.  Intrauterine growth retardation.

Authors:  M L Chiswick
Journal:  Br Med J (Clin Res Ed)       Date:  1985-09-28

9.  Prenatal predictors of cesarean section due to labor arrest.

Authors:  D M Harper; C A Johnson; W H Harper; B S Liese
Journal:  Arch Gynecol Obstet       Date:  1995       Impact factor: 2.344

10.  Full-Term Small-for-Gestational-Age Newborns in the U.S.: Characteristics, Trends, and Morbidity.

Authors:  Alexander C Ewing; Sascha R Ellington; Carrie K Shapiro-Mendoza; Wanda D Barfield; Athena P Kourtis
Journal:  Matern Child Health J       Date:  2017-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.