Literature DB >> 6821901

Myocardial contrast echocardiography: a reproducible technique of myocardial opacification for identifying regional perfusion deficits.

C Tei, T Sakamaki, P M Shah, S Meerbaum, K Shimoura, S Kondo, E Corday.   

Abstract

The effects and reliability of a simple method of contrast two-dimensional echocardiographic delineation of myocardium after intracoronary injections were evaluated in closed-chest dogs. Multiple injections of an agitated saline-Renografin (meglumine diatrizoate) mixture (3:2 ratio, 2-ml bolus) into the left main coronary artery as well as at different sites of the left anterior descending and circumflex coronary arteries were studied in several short-axis and long-axis cross sections of the left ventricle. These contrast injections opacified specific regions of left ventricular myocardium depending on the site of injection. Contrast injection into the left main coronary artery provided a clear, echo-free outline (negative contrast) of underperfused myocardium distal to the coronary occlusion. Reproducibility studies of the extent of involved zones measured in echocardiographic cross sections indicated high intra- and interobserver correlation coefficients (r = 0.97 and 0.97). The effects of the intracoronary injection of contrast material appeared minor and brief. ECG ST-T changes lasted 49.4 +/- 36.7 seconds, aortic systolic pressure was reduced by 7.6 +/- 4.4% for 18.9 +/- 4.8 seconds, and the peak rate of left ventricular pressure rise decreased by 14.3 +/- 2.6%, but returned to control levels within 19.4 +/- 6.1 seconds. The zone of left ventricular asynergy after coronary occlusions was also delineated by cross-sectional echocardiography and corresponded to the contrast-outlined underperfused zone (negative contrast). This new intracoronary echocardiographic technique has only minor hemodynamic consequences and provides reliable quantitation of underperfused and dysfunctioning zones after experimental coronary occlusions. Further investigation and validation of this method may provide useful characterization of the extent and severity of myocardial ischemia and infarction.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6821901     DOI: 10.1161/01.cir.67.3.585

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  19 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  [Noninvasive determination of coronary flow reserve with signal enhanced high resolution transthoracic Doppler color echocardiography].

Authors:  H Lambertz; J Bönhof; J Brechtken; T Stein; H P Tries; H Lethen
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

Review 6.  Contrast enhanced ultrasound imaging.

Authors:  Steven B Feinstein; Blai Coll; Daniel Staub; Dan Adam; Arend F L Schinkel; Folkert J ten Cate; Kai Thomenius
Journal:  J Nucl Cardiol       Date:  2010 Jan-Feb       Impact factor: 5.952

7.  Assessment of myocardial perfusion and systolic function in patients with coronary artery disease after coronary artery bypass surgery by myocardial contrast echocardiography and two-dimensional strain echocardiography.

Authors:  Rong Liu; Youbin Deng; Xiaojun Bi; Yani Liu; Li Xiong; Liuping Chen
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2009-10-11

Review 8.  Contrast echocardiography 1996. A review.

Authors:  H R Villarraga; D A Foley; S L Mulvagh
Journal:  Tex Heart Inst J       Date:  1996

9.  In vivo magnetic resonance vascular imaging using laser-polarized 3He microbubbles.

Authors:  M S Chawla; X J Chen; H E Möller; G P Cofer; C T Wheeler; L W Hedlund; G A Johnson
Journal:  Proc Natl Acad Sci U S A       Date:  1998-09-01       Impact factor: 11.205

10.  Clinical methods to determine coronary flow and myocardial perfusion.

Authors:  M J Wolters-Geldof; V M Cats; A V Bruschke
Journal:  Int J Card Imaging       Date:  1997-04