Comparison of late (62 to 140 months) degenerative changes in simultaneously implanted and explanted porcine (Hancock) bioprostheses in the tricuspid and mitral valve positions in six patients.

S R Cohen, M A Silver, C L McIntosh, W C Roberts.   

Abstract

A Hancock porcine bioprosthesis (PB) was simultaneously implanted in each of 6 patients aged 30 to 64 years (mean 45) in the tricuspid and mitral valve positions and both PBs were explanted 62 to 140 months (mean 102) later. Cuspal degenerative changes occurred in all 12 PBs. In 5 patients, the changes were more extensive on the PBs in the mitral position than in those in the tricuspid position. Cuspal calcific deposits, as determined by radiographs of the explanted bioprostheses, occurred in 5 PBs in the mitral position and in 3 in the tricuspid position: 1 patient with calcific deposits in the PB in the mitral position had no calcific deposits in the corresponding PB in the tricuspid position; 1 patient had heavy calcific deposits in the PB in the mitral position and only mild deposits in the PB in the tricuspid position; and 3 patients had similar but mild calcific deposits in both PBs. Cuspal tears occurred in 5 of the 6 PBs in the mitral position and in no PB in the tricuspid position. Thrombus was observed on the ventricular aspects of the bioprosthetic cusps in 1 PB in the mitral position and in 4 PBs in the tricuspid position. Thus, in our 6 patients, the degenerative changes were more extensive in the PBs in the mitral position than in those in the tricuspid position. These observations indicate that wear characteristics of simultaneously implanted PBs vary according to the site of implantation.

Entities:  

Mesh:

Year:  1984        PMID: 6731305     DOI: 10.1016/0002-9149(84)90586-1

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Long-term results of porcine bioprostheses in the tricuspid position.

Authors:  K Kuwaki; K Komatsu; K Morishita; M Tsukamoto; T Abe
Journal:  Surg Today       Date:  1998       Impact factor: 2.549

2.  Influence of pressure load on durability of pulmonic xenobioprostheses in young adults.

Authors:  Nobuyuki Takagi; Kazutoshi Tachibana; Yasuko Miyagi; Akihiko Yamauchi; Satoshi Muraki; Tetsuya Higami
Journal:  J Artif Organs       Date:  2011-07-07       Impact factor: 1.731

Review 3.  Evidence-based surgical management of acquired tricuspid valve disease.

Authors:  Sung Ho Shinn; Hartzell V Schaff
Journal:  Nat Rev Cardiol       Date:  2013-02-12       Impact factor: 32.419

4.  Comparative studies of prosthetic materials in the left atrium of the dog.

Authors:  M H Kadowaki; J M Levett; D L Manjoney; C A Wilson; S Glagov
Journal:  Virchows Arch A Pathol Anat Histopathol       Date:  1987
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.