Literature DB >> 21735151

Influence of pressure load on durability of pulmonic xenobioprostheses in young adults.

Nobuyuki Takagi1, Kazutoshi Tachibana, Yasuko Miyagi, Akihiko Yamauchi, Satoshi Muraki, Tetsuya Higami.   

Abstract

The aim of this study was to investigate the effects of pressure load (pulmonary arterial pressure) on the long-term durability of second-generation xenobioprostheses in the pulmonary position in young adults. Thirteen patients survived pulmonary valve replacement for pulmonary regurgitation using the second-generation aortic porcine bioprosthesis at Sapporo Medical University School of Medicine between 1985 and 2009. The mean age at pulmonary valve replacement was 40.5 years, and the mean prosthetic valve size was 25.3 mm. Two patients developed structural valve deterioration 6 and 9 years, respectively, after pulmonary valve replacement. Both prosthetic valves with structural valve deterioration were subjected to long-term high levels of pressure load. No valve structural failure was observed in the remaining 11 patients who experience low-pressure load during a mean follow-up period of 11.9 years. The freedom from structural valve deterioration at 15 years was 75.8% for the overall population, but 100% for those with low-pressure load. Our findings suggest that the long-term durability of pulmonary-site bioprosthetic valves in young adult patients is promising but that pressure load might be a risk of the limited durability of the valve.

Entities:  

Mesh:

Year:  2011        PMID: 21735151     DOI: 10.1007/s10047-011-0582-8

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  11 in total

1.  Independent factors associated with longevity of prosthetic pulmonary valves and valved conduits.

Authors:  C A Caldarone; B W McCrindle; G S Van Arsdell; J G Coles; G Webb; R M Freedom; W G Williams
Journal:  J Thorac Cardiovasc Surg       Date:  2000-12       Impact factor: 5.209

2.  Isolated pulmonary valve replacement: analysis of 27 years of experience.

Authors:  Shigehiko Tokunaga; Munetaka Masuda; Akira Shiose; Yukihiro Tomita; Shigeki Morita; Ryuji Tominaga
Journal:  J Artif Organs       Date:  2008-10-05       Impact factor: 1.731

3.  Pulmonary valve replacement late after repair of tetralogy of Fallot.

Authors:  I M Yemets; W G Williams; G D Webb; D A Harrison; P R McLaughlin; G A Trusler; J G Coles; I M Rebeyka; R M Freedom
Journal:  Ann Thorac Surg       Date:  1997-08       Impact factor: 4.330

4.  Long-term results of porcine valve insertion for pulmonary regurgitation following repair of tetralogy of Fallot.

Authors:  M N Ilbawi; F S Idriss; S Y DeLeon; A J Muster; T E Berry; M H Paul
Journal:  Ann Thorac Surg       Date:  1986-05       Impact factor: 4.330

5.  Carpentier-Edwards supra-annular aortic porcine bioprosthesis: clinical performance over 20 years.

Authors:  W R Eric Jamieson; Lawrence H Burr; Robert T Miyagishima; Eva Germann; Joan S Macnab; Elizabeth Stanford; Florence Chan; Michael T Janusz; Hilton Ling
Journal:  J Thorac Cardiovasc Surg       Date:  2005-10       Impact factor: 5.209

6.  Improved right ventricular function following late pulmonary valve replacement for residual pulmonary insufficiency or stenosis.

Authors:  E L Bove; R E Kavey; C J Byrum; H M Sondheimer; M S Blackman; F D Thomas
Journal:  J Thorac Cardiovasc Surg       Date:  1985-07       Impact factor: 5.209

7.  Pulmonary valve insertion during reoperation for tetralogy of Fallot.

Authors:  S J Finck; F J Puga; G K Danielson
Journal:  Ann Thorac Surg       Date:  1988-06       Impact factor: 4.330

8.  Comparison of late (62 to 140 months) degenerative changes in simultaneously implanted and explanted porcine (Hancock) bioprostheses in the tricuspid and mitral valve positions in six patients.

Authors:  S R Cohen; M A Silver; C L McIntosh; W C Roberts
Journal:  Am J Cardiol       Date:  1984-06-01       Impact factor: 2.778

9.  Porcine heterograft valve replacement in children.

Authors:  D B Williams; G K Danielson; D C McGoon; F J Puga; D D Mair; W D Edwards
Journal:  J Thorac Cardiovasc Surg       Date:  1982-09       Impact factor: 5.209

10.  Pulmonary site bioprostheses: morphologic findings in 40 cases.

Authors:  Gursharan S Soor; Shaun W Leong; Jagdish Butany; Jonathan L Shapero; William G Williams
Journal:  Arch Pathol Lab Med       Date:  2009-05       Impact factor: 5.534

View more
  1 in total

Review 1.  Journal of Artificial Organs 2011: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; A Myoui; M Nishimura; T Nishimura; S Tokunaga; Y Tomizawa; T Tomo; T Tsukiya; T Yamaoka
Journal:  J Artif Organs       Date:  2012-02-29       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.