Literature DB >> 6723003

Effect of arterial impedance changes on the end-systolic pressure-volume relation.

W L Maughan, K Sunagawa, D Burkhoff, K Sagawa.   

Abstract

To study the end-systolic pressure-volume relationship of left ventricle ejection against physiological afterload, we imposed seven simulated arterial impedances on excised canine left ventricles connected to a newly developed servo-pump system. We set each of the impedance parameters (resistance, capacitance, and characteristic impedance) to 50, 100, and 200% of normal value (resistance: 3 mm Hg sec/ml; capacitance: 0.4 ml/mm Hg; characteristic impedance: 0.2 mm Hg sec/ml), while leaving the other parameters normal. Under a given impedance, the end-systolic pressure-volume relationship was determined by preloading the ventricle at four different end-diastolic volumes. There was no significant change in the slope of the end-systolic pressure-volume relationship with changes in any of the afterloading impedance parameters. However, the volume intercept of the end-systolic pressure-volume relationship decreased significantly with resistance from 5.5 +/- 1.0 (SE) ml at resistance equal to 1.5 mm Hg sec/ml to 0.6 +/- 1.8 ml at resistance equal to 6 mm Hg sec/ml (P less than 0.01). The volume axis intercept also decreased with characteristic impedance, from 5.9 +/- 2.0 ml at a characteristic impedance of 0.1 mm Hg sec/ml to 5.4 +/- 2.1 ml at a characteristic impedance of 0.4 mm Hg sec/ml, (P less than 0.05). We conclude that the slope of the end-systolic pressure-volume relationship is insensitive to a wide range of changes in afterload impedance, but its volume intercept is dependent on resistance and characteristic impedance.

Entities:  

Mesh:

Year:  1984        PMID: 6723003     DOI: 10.1161/01.res.54.5.595

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  25 in total

1.  A new pulse duplicator with a passive fill ventricle for analysis of cardiac dynamics.

Authors:  Yoshimasa Yokoyama; Osamu Kawaguchi; Tadahiko Shinshi; Ulrich Steinseifer; Setsuo Takatani
Journal:  J Artif Organs       Date:  2010-09-28       Impact factor: 1.731

Review 2.  Ventricular pressure-volume relations as the primary basis for evaluation of cardiac mechanics. Return to Frank's diagram.

Authors:  R Jacob; G Kissling
Journal:  Basic Res Cardiol       Date:  1989 May-Jun       Impact factor: 17.165

3.  The step response of left ventricular pressure to ejection flow: a system oriented approach.

Authors:  H B Boom; H Wijkstra
Journal:  Ann Biomed Eng       Date:  1992       Impact factor: 3.934

Review 4.  Ventriculo-arterial coupling: concepts, assumptions, and applications.

Authors:  D A Kass; R P Kelly
Journal:  Ann Biomed Eng       Date:  1992       Impact factor: 3.934

Review 5.  Deep Phenotyping of Systemic Arterial Hemodynamics in HFpEF (Part 1): Physiologic and Technical Considerations.

Authors:  Julio A Chirinos
Journal:  J Cardiovasc Transl Res       Date:  2017-02-16       Impact factor: 4.132

6.  Ventricular-arterial coupling: Invasive and non-invasive assessment.

Authors:  Julio A Chirinos
Journal:  Artery Res       Date:  2013-03       Impact factor: 0.597

Review 7.  Pulsatile arterial haemodynamics in heart failure.

Authors:  Thomas Weber; Julio A Chirinos
Journal:  Eur Heart J       Date:  2018-11-14       Impact factor: 29.983

8.  Some applications of the P-V relation to the study of left ventricular performance.

Authors:  R M Shoucri; J R Rouleau; J G Kingma; J G Dumesnil; G R Dagenais
Journal:  Bull Math Biol       Date:  1989       Impact factor: 1.758

9.  Comparison of effects of dobutamine and ouabain on left ventricular contraction and relaxation in closed-chest dogs.

Authors:  W C Little; A Rassi; G L Freeman
Journal:  J Clin Invest       Date:  1987-09       Impact factor: 14.808

10.  Cardiovascular sequelae of endotoxin shock in diabetic dogs.

Authors:  W R Law; M T Moriarty; M P McLane
Journal:  Diabetologia       Date:  1991-10       Impact factor: 10.122

View more