The computation of scatter in mammography by Monte Carlo methods.

D R Dance, G J Day.   

Abstract

A Monte Carlo computer program has been used to calculate the ratio of the scatter-to-primary radiation recorded by a range of image receptors used in mammography. The dependence of this ratio on breast size and photon energy has been investigated and the contributions of different sources of scattered radiation examined. The use of magnification and grid techniques have been included in the program and the performance of the Philips mammographic grid examined in detail. The results of the calculations are in good agreement with the limited experimental data available.

Mesh:

Year:  1984        PMID: 6709703     DOI: 10.1088/0031-9155/29/3/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Scatter radiation in digital tomosynthesis of the breast.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

2.  The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(TI) full-field flat panel detector.

Authors:  Ann-Katherine Carton; Raymond Acciavatti; Johnny Kuo; Andrew D A Maidment
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  Comparison of slot scanning digital mammography system with full-field digital mammography system.

Authors:  Chao-Jen Lai; Chris C Shaw; William Geiser; Lingyun Chen; Elsa Arribas; Tanya Stephens; Paul L Davis; Geetha P Ayyar; Basak E Dogan; Victoria A Nguyen; Gary J Whitman; Wei T Yang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

4.  On image quality metrics and the usefulness of grids in digital mammography.

Authors:  Han Chen; Mats Danielsson; Cheng Xu; Björn Cederström
Journal:  J Med Imaging (Bellingham)       Date:  2015-02-17

5.  A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

6.  Monochromatic mammography using scanning multilayer X-ray mirrors.

Authors:  David L Windt
Journal:  Rev Sci Instrum       Date:  2018-08       Impact factor: 1.523

7.  Effect of image quality on calcification detection in digital mammography.

Authors:  Lucy M Warren; Alistair Mackenzie; Julie Cooke; Rosalind M Given-Wilson; Matthew G Wallis; Dev P Chakraborty; David R Dance; Hilde Bosmans; Kenneth C Young
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

8.  Power spectrum analysis of the x-ray scatter signal in mammography and breast tomosynthesis projections.

Authors:  Ioannis Sechopoulos; Kristina Bliznakova; Baowei Fei
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.