Monochromatic mammography using scanning multilayer X-ray mirrors.

David L Windt1.   

Abstract

A prototype system for breast imaging using monochromatic X-rays has been developed using a scanning multilayer X-ray mirror in combination with a conventional mammography tube and an imaging detector. The X-ray mirror produces a monochromatic fan beam tuned near 19 keV, with an energy bandpass of approximately 1.5 keV. Rotating the mirror about the tube's focal spot in synchronization with the X-ray generator and detector enables the acquisition of monochromatic X-ray images over large areas. The X-ray mirror also can be rotated completely out of the beam so that conventional polychromatic images can be acquired using a K-edge filter, facilitating direct comparison between the two modes of operation. The system was used to image synthetic, tissue-equivalent breast phantoms in order to experimentally quantify the improvements in image quality and dose that can be realized using monochromatic radiation. Nine custom phantoms spanning a range of thicknesses and glandular/adipose ratios, each containing both glandular- and calcification-equivalent features, were used to measure contrast and signal-difference-to-noise ratio (SDNR). Mean glandular dose (MGD) was computed from measured entrance exposure, and a figure-of-merit (FOM) was computed as FOM = SDNR2/MGD in each case. Monochromatic MGD ranges from 0.606 to 0.134 of polychromatic MGD for images having comparable glandular SDNR, depending on breast thickness and glandularity; relative monochromatic dose decreases with increasing glandularity for all thicknesses. Monochromatic FOM values are higher than the corresponding polychromatic FOM values in all but one case. Additionally, the monochromatic contrast for glandular features is higher than the polychromatic contrast in all but one case as well. These results represent important steps toward the realization of clinically practical monochromatic X-ray breast imaging systems having lower dose and better image quality, including those for digital mammography, digital breast tomosynthesis, contrast-enhanced spectral mammography and other modalities, for safer, more accurate breast cancer detection, diagnosis and staging.

Entities:  

Mesh:

Year:  2018        PMID: 30184654      PMCID: PMC6095706          DOI: 10.1063/1.5041799

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  21 in total

1.  Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment.

Authors:  J M Boone
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

2.  Normalized glandular dose (DgN) coefficients for arbitrary X-ray spectra in mammography: computer-fit values of Monte Carlo derived data.

Authors:  John M Boone
Journal:  Med Phys       Date:  2002-05       Impact factor: 4.071

3.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

4.  Beam collimation with polycapillary x-ray optics for high contrast high resolution monochromatic imaging.

Authors:  Francisca R Sugiro; Danhong Li; C A MacDonald
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

5.  An improved method for flat-field correction of flat panel x-ray detector.

Authors:  Alexander L C Kwan; J Anthony Seibert; John M Boone
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

6.  Induction of angiogenesis during the transition from hyperplasia to neoplasia.

Authors:  J Folkman; K Watson; D Ingber; D Hanahan
Journal:  Nature       Date:  1989-05-04       Impact factor: 49.962

7.  A model for optimization of spectral shape in digital mammography.

Authors:  R Fahrig; M J Yaffe
Journal:  Med Phys       Date:  1994-09       Impact factor: 4.071

8.  Direct measurement of mammographic x-ray spectra using a CdZnTe detector.

Authors:  M Matsumoto; A Yamamoto; I Honda; A Taniguchi; H Kanamori
Journal:  Med Phys       Date:  2000-07       Impact factor: 4.071

9.  Mammography with synchrotron radiation: first clinical experience with phase-detection technique.

Authors:  Edoardo Castelli; Maura Tonutti; Fulvia Arfelli; Renata Longo; Emilio Quaia; Luigi Rigon; Daniela Sanabor; Fabrizio Zanconati; Diego Dreossi; Alessando Abrami; Elisa Quai; Paola Bregant; Katia Casarin; Valentina Chenda; Ralf Hendrik Menk; Tatjana Rokvic; Alessandro Vascotto; Giuliana Tromba; Maria Assunta Cova
Journal:  Radiology       Date:  2011-03-24       Impact factor: 11.105

10.  Monochromatic computed tomography with a compact laser-driven X-ray source.

Authors:  K Achterhold; M Bech; S Schleede; G Potdevin; R Ruth; R Loewen; F Pfeiffer
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.