Literature DB >> 670407

Determination of antibiotic sensitivities by the Sensititre system.

I Phillips, C Warren, P M Waterworth.   

Abstract

The Sensititre system provides antibiotics dried in microtitre trays in appropriate concentrations for the determination of minimum inhibitory concentrations (MIC) when organisms are added in liquid culture medium and incubated overnight. Results with a variety of media--for Gram-negative bacilli tested with ampicillin, carbenicillin, cephaloridine, and gentamicin, staphylococci with penicillin, cloxacillin, fusidic acid, and gentamicin, and streptococci with penicillin, ampicillin, cephaloridine, and erythromycin--were usually very similar to those of agar dilution tests. Discrepant results are found in a few situations, and in some cases, especially those involving borderline resistance to fusidic acid and gentamicin among staphylococci and Gram-negative bacilli, we have been unable to suggest modfication to produce the right results. Despite these problems, fortunately few and identifiable, we recommend the system especially for use in laboratories that determine the MICs infrequently.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 670407      PMCID: PMC1145340          DOI: 10.1136/jcp.31.6.531

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  6 in total

1.  Evaluation of the MicroScan antimicrobial susceptibility system with the autoSCAN-4 automated reader.

Authors:  C N Baker; S A Stocker; D L Rhoden; C Thornsberry
Journal:  J Clin Microbiol       Date:  1986-01       Impact factor: 5.948

2.  Susceptibility studies of multiply resistant Haemophilus influenzae isolated from pediatric patients and contacts.

Authors:  J Campos; S Garcia-Tornel; I Sanfeliu
Journal:  Antimicrob Agents Chemother       Date:  1984-06       Impact factor: 5.191

3.  Evaluation of the AutoSCAN-3, a device for reading microdilution trays.

Authors:  P C DeGirolami; K A Eichelberger; L C Salfity; M F Rizzo
Journal:  J Clin Microbiol       Date:  1983-12       Impact factor: 5.948

4.  Evaluation of the Sceptor microdilution antibiotic susceptibility testing system: a collaborative investigation.

Authors:  R N Jones; C Thornsberry; A L Barry; T L Gavan
Journal:  J Clin Microbiol       Date:  1981-01       Impact factor: 5.948

5.  Evaluation of the Sensititre system for quantitative antimicrobial drug susceptibility testing: a collaborative study.

Authors:  T L Gavan; R N Jones; A L Barry
Journal:  Antimicrob Agents Chemother       Date:  1980-03       Impact factor: 5.191

6.  Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.

Authors:  J M Boyce; L S Lytle; D A Walsh
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

  6 in total