Literature DB >> 6699034

Isolation of serum protein organometallic corrosion products from 316LSS and HS-21 in vitro and in vivo.

J L Woodman, J Black, S A Jiminez.   

Abstract

An investigation into blood-borne organometallic compounds that arise from the corrosion of metals used in orthopedic prosthetic devices was conducted using an in vivo rat model with an implantation time of 10 days and an in vitro human serum model with an incubation time of 5 days. Both models involved 316LSS and HS-21 in the spherical powder form of 55 +/- 5 microns microns in diameter at three different surface areas to body weight ratios. Gel chromatography on cross-linked dextran (G-200) was used to fractionate the serum proteins which bound the metal ions (chromium, cobalt, and nickel) released and identify them. Atomic absorption-spectrophotometry analysis measured the concentration of the metal ions in each serum protein peak as well as whole serum from both models, and red cell and tissue from the in vivo model. Within the serum proteins, the metal ions were bound to two of the principal serum protein peaks. Similar distributions of the metals among the serum protein peaks were not noted.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6699034     DOI: 10.1002/jbm.820180110

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  8 in total

1.  Biotherapeutic formulation factors affecting metal leachables from stainless steel studied by design of experiments.

Authors:  Shuxia Zhou; Brad Evans; Christian Schöneich; Satish K Singh
Journal:  AAPS PharmSciTech       Date:  2012-01-13       Impact factor: 3.246

Review 2.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

3.  Surface-protein interactions on different stainless steel grades: effects of protein adsorption, surface changes and metal release.

Authors:  Y Hedberg; X Wang; J Hedberg; M Lundin; E Blomberg; I Odnevall Wallinder
Journal:  J Mater Sci Mater Med       Date:  2013-02-02       Impact factor: 3.896

4.  The influence of complexing agent and proteins on the corrosion of stainless steels and their metal components.

Authors:  Aleksandra Kocijan; Ingrid Milosev; Boris Pihlar
Journal:  J Mater Sci Mater Med       Date:  2003-01       Impact factor: 3.896

5.  The study of metal ion release and cytotoxicity in Co-Cr-Mo and Ti-Al-V alloy in total knee prosthesis - scanning electron microscopic observation.

Authors:  Shizuko Ichinose; Takeshi Muneta; Ichiro Sekiya; Soichiro Itoh; Hideki Aoki; Motoki Tagami
Journal:  J Mater Sci Mater Med       Date:  2003-01       Impact factor: 3.896

6.  Titanium transport through the blood stream. An experimental study on rats.

Authors:  Daniel G Olmedo; Débora Tasat; María B Guglielmotti; Rómulo L Cabrini
Journal:  J Mater Sci Mater Med       Date:  2003-12       Impact factor: 3.896

7.  CoCrMo metal-on-metal hip replacements.

Authors:  Yifeng Liao; Emily Hoffman; Markus Wimmer; Alfons Fischer; Joshua Jacobs; Laurence Marks
Journal:  Phys Chem Chem Phys       Date:  2013-01-21       Impact factor: 3.676

8.  Effect of the coexistence of albumin and H2O2 on the corrosion of biomedical cobalt alloys in physiological saline.

Authors:  Weichen Xu; Binbin Zhang; Lihui Yang; Qiancheng Ni; Yantao Li; Fei Yu
Journal:  RSC Adv       Date:  2019-10-15       Impact factor: 4.036

  8 in total