Literature DB >> 6684181

Microtransducer urethral profile methodology: variations caused by transducer orientation.

R S Anderson, A M Shepherd, R C Feneley.   

Abstract

Microtip catheters are being used increasingly for measurement of the urethral pressure profile. The orientation of the pressure sensor is critical and attention is drawn to variations of the measured parameters in different sensor positions. A standardization of transducer orientation is necessary and the lateral (9 o'clock) position is suggested.

Entities:  

Mesh:

Year:  1983        PMID: 6684181     DOI: 10.1016/s0022-5347(17)51425-1

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  17 in total

1.  Urethral resistance measurement: a new method for evaluation of stress urinary incontinence in women.

Authors:  V Herrmann; L A Arya; D L Myers; N D Jackson; P C Palma; C L Riccetto
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2004-03-30

2.  Air-charged and microtransducer urodynamic catheters in the evaluation of urethral function.

Authors:  Jennifer T Pollak; Minda Neimark; Jason T Connor; G Willy Davila
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2004-02-03

3.  Computer assisted pantropic urethral pressure profile.

Authors:  M Cornelissen; E M Jacquemyn; R L Vereecken
Journal:  Urol Res       Date:  1989

4.  Fluid perfused urethral pressure profilometry and Valsalva leak point pressure: a comparative study in a biophysical model of the urethra.

Authors:  Tim Idzenga; Johan J M Pel; Ron van Mastrigt
Journal:  World J Urol       Date:  2007-06-19       Impact factor: 4.226

5.  Submaximal pelvic floor muscle contractions: similar bladder-neck elevation, longer duration, less intra-abdominal pressure.

Authors:  Baerbel Junginger; Hanna Vollhaber; Kaven Baessler
Journal:  Int Urogynecol J       Date:  2018-08-01       Impact factor: 2.894

6.  Urethral pressure variations in healthy male volunteers.

Authors:  H J Kirkeby; S Sørensen; E U Poulsen
Journal:  Urol Res       Date:  1989

7.  Effects of phosphodiesterase type 5 inhibitor, tadalafil, on continence reflex in rats.

Authors:  Hideaki Izumi; Yasuhiro Kaiho; Minoru Miyazato; Naoki Kawamorita; Haruo Nakagawa; Yoichi Arai
Journal:  Int Urogynecol J       Date:  2014-07-03       Impact factor: 2.894

8.  Development of a novel intra-vaginal transducer with improved dynamic response.

Authors:  Paul J Johnson; Evan M Rosenbluth; Ingrid E Nygaard; Monir K Parikh; Robert W Hitchcock
Journal:  Biomed Microdevices       Date:  2009-12       Impact factor: 2.838

9.  Development and testing of a vaginal pressure sensor to measure intra-abdominal pressure in women.

Authors:  Evan M Rosenbluth; Paul J Johnson; Robert W Hitchcock; Ingrid E Nygaard
Journal:  Neurourol Urodyn       Date:  2010-04       Impact factor: 2.696

10.  Urethral sleeve sensor: a non-withdrawal method to measure maximum urethral pressure.

Authors:  Jasmine Tan-Kim; Milena M Weinstein; Charles W Nager
Journal:  Int Urogynecol J       Date:  2010-01-14       Impact factor: 2.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.