Literature DB >> 15014940

Air-charged and microtransducer urodynamic catheters in the evaluation of urethral function.

Jennifer T Pollak1, Minda Neimark, Jason T Connor, G Willy Davila.   

Abstract

This study aimed to compare measurements of urethral pressure profile and Valsalva leak point pressure (VLPP) obtained with air-charged and microtransducer catheters. Forty-five women with urogynecologic dysfunction underwent multichannel urodynamic evaluation including maximum urethral closure pressure (MUCP), functional urethral length (FUL), and VLPP with air-charged balloon catheters as well as microtransducer catheters. Lin's concordance coefficient was used to examine the agreement of MUCP, VLPP, and FUL measurements with the two catheters. The MUCPs measured with the two catheters had a high concordance coefficient of 0.69 (95% CI 0.50, 0.82). The VLPP measurements obtained with the catheters also agreed well, with a concordance coefficient of 0.71 (95% CI 0.43, 0.87). The measurements of mean FUL had a low concordance of 0.35 (95% CI 0.085, 0.57). Overall, air-charged and microtransducer catheters yield similar information when evaluating VLPP and MUCP. There were differences in FUL and these were likely due to different catheter diameters.

Entities:  

Mesh:

Year:  2004        PMID: 15014940     DOI: 10.1007/s00192-004-1121-4

Source DB:  PubMed          Journal:  Int Urogynecol J Pelvic Floor Dysfunct


  6 in total

1.  Comparison of microtransducer and fiberoptic catheters for urodynamic studies.

Authors:  P J Culligan; R P Goldberg; D W Blackhurst; K Sasso; S Koduri; P K Sand
Journal:  Obstet Gynecol       Date:  2001-08       Impact factor: 7.661

2.  Standardisation of urethral pressure measurement: report from the Standardisation Sub-Committee of the International Continence Society.

Authors:  Gunnar Lose; Derek Griffiths; Gordon Hosker; Sigurd Kulseng-Hanssen; Daniele Perucchini; Werner Schäfer; Peter Thind; Eboo Versi
Journal:  Neurourol Urodyn       Date:  2002       Impact factor: 2.696

3.  A concordance correlation coefficient to evaluate reproducibility.

Authors:  L I Lin
Journal:  Biometrics       Date:  1989-03       Impact factor: 2.571

4.  The standardisation of terminology of lower urinary tract function. The International Continence Society Committee on Standardisation of Terminology.

Authors:  P Abrams; J G Blaivas; S L Stanton; J T Andersen
Journal:  Scand J Urol Nephrol Suppl       Date:  1988

5.  Microtransducer urethral profile methodology: variations caused by transducer orientation.

Authors:  R S Anderson; A M Shepherd; R C Feneley
Journal:  J Urol       Date:  1983-10       Impact factor: 7.450

6.  Discriminant analysis of urethral pressure profilometry data for the diagnosis of genuine stress incontinence.

Authors:  E Versi
Journal:  Br J Obstet Gynaecol       Date:  1990-03
  6 in total
  10 in total

1.  Comment: are the measurements of water-filled and air-charged catheters the same in urodynamics?

Authors:  Françoise A Valentini
Journal:  Int Urogynecol J       Date:  2014-01       Impact factor: 2.894

2.  Balloon-tipped catheter for measuring urethral pressures.

Authors:  James S Walter; John S Wheeler; Xiaoli Wang; Robert D Wurster
Journal:  J Spinal Cord Med       Date:  2009       Impact factor: 1.985

3.  Measurement of dynamic urethral pressures with a high-resolution manometry system in continent and incontinent women.

Authors:  Anna C Kirby; Jasmine Tan-Kim; Charles W Nager
Journal:  Female Pelvic Med Reconstr Surg       Date:  2015 Mar-Apr       Impact factor: 2.091

4.  Are the measurements of water-filled and air-charged catheters the same in urodynamics?

Authors:  G Alessandro Digesu; Alexandros Derpapas; Penny Robshaw; Gopalan Vijaya; Caroline Hendricken; Vik Khullar
Journal:  Int Urogynecol J       Date:  2013-08-01       Impact factor: 2.894

5.  An inelastic retropubic suburethral sling in women with intrinsic sphincter deficiency.

Authors:  Alfredo Jijon; Aparna Hegde; Beatriz Arias; Vivian Aguilar; G Willy Davila
Journal:  Int Urogynecol J       Date:  2012-12-11       Impact factor: 2.894

6.  Correlation of maximum urethral closure pressure with Valsalva leak point pressure using air-charged urodynamic catheters.

Authors:  Terry White; Amie Kawasaki; Reneita V Ross; Rony A Adam; Thinh H Duong
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2009-05-15

7.  Head-to-head comparison of pressures during full cystometry, with clinical as well as in-depth signal-analysis, of air-filled catheters versus the ICS-standard water-filled catheters.

Authors:  Peter F W M Rosier
Journal:  Neurourol Urodyn       Date:  2021-08-07       Impact factor: 2.367

Review 8.  Optical Fibre Pressure Sensors in Medical Applications.

Authors:  Sven Poeggel; Daniele Tosi; DineshBabu Duraibabu; Gabriel Leen; Deirdre McGrath; Elfed Lewis
Journal:  Sensors (Basel)       Date:  2015-07-15       Impact factor: 3.576

9.  The Effect of Botulinum Toxin Type A Injections on Stricture Formation, Leakage Rates, Esophageal Elongation, and Anastomotic Healing Following Primary Anastomosis in a Long- and Short-Gap Esophageal Atresia Model - A Protocol for a Randomized, Controlled, Blinded Trial in Pigs.

Authors:  Emma Svensson; Peter Zvara; Niels Qvist; Lars Hagander; Sören Möller; Lars Rasmussen; Henrik Daa Schrøder; Eva Kildall Hejbøl; Niels Bjørn; Súsanna Petersen; Kristine Cederstrøm Larsen; Jan Krhut; Oliver J Muensterer; Mark Bremholm Ellebæk
Journal:  Int J Surg Protoc       Date:  2021-08-11

10.  Signal processing in urodynamics: towards high definition urethral pressure profilometry.

Authors:  Mario Klünder; Oliver Sawodny; Bastian Amend; Michael Ederer; Alexandra Kelp; Karl-Dietrich Sievert; Arnulf Stenzl; Ronny Feuer
Journal:  Biomed Eng Online       Date:  2016-03-22       Impact factor: 2.819

  10 in total