Literature DB >> 6664676

Potential acuity meter using a minute aerial pinhole aperture.

J S Minkowski, M Palese, D L Guyton.   

Abstract

A new instrument allows accurate measurement of retinal visual acuity behind mild to moderate cataracts. Mounted on a slit lamp, the Potential Acuity Meter projects a Snellen visual acuity chart into the eye via a narrow beam of light converging to a minute aerial aperture only 0.15 mm in diameter. The examiner aims the narrow beam through "windows" in the cataract, avoiding blockage or scattering of the light that would otherwise occur. In 47 cataractous eyes having best preoperative visual acuity of 20/200 and better, the postoperative visual acuity was predicted to within three lines in 100% of cases, and to within two lines in 91%. With a successful result from cataract surgery defined as postoperative vision of 20/40 or better, the prediction of success with the Potential Acuity Meter was correct in 95% of cases.

Entities:  

Mesh:

Year:  1983        PMID: 6664676     DOI: 10.1016/s0161-6420(83)34381-5

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  15 in total

1.  Use of 10-Hz flash visual evoked potentials in prediction of final visual acuity in diabetic eyes with vitreous hemorrhage.

Authors:  V L Vadrevu; S Cavender; J V Odom
Journal:  Doc Ophthalmol       Date:  1992       Impact factor: 2.379

2.  Predictions of postoperative visual outcome in subjects with cataract: a preoperative and postoperative study.

Authors:  William A Douthwaite; Marta Vianya-Estopà; David B Elliott
Journal:  Br J Ophthalmol       Date:  2006-11-23       Impact factor: 4.638

3.  Comparison of distance and near visual acuity in patients with vision loss due to cataract.

Authors:  Carmel L Mercado; Pavle Doroslovački; Jiangxia Wang; Aazim A Siddiqui; Andrew F Kolker; Richard J Kolker
Journal:  Int Ophthalmol       Date:  2016-05-10       Impact factor: 2.031

Review 4.  Assessing retinal/neural function in the presence of ocular media opacities.

Authors:  P V McGraw; B T Barrett
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-04       Impact factor: 3.117

5.  Longitudinal comparison of visual acuity as measured by the ETDRS chart and by the potential acuity meter in eyes with macular edema, and its relationship with retinal thickness and sensitivity.

Authors:  E Hatef; M Hanout; A Moradi; E Colantuoni; M Bittencourt; H Liu; Y J Sepah; M Ibrahim; D V Do; D L Guyton; Q D Nguyen
Journal:  Eye (Lond)       Date:  2014-08-08       Impact factor: 3.775

6.  Electrophysiological findings in delayed discovery of a metallic intraocular foreign body in a child: case report.

Authors:  Felipe Pereira; Licia Matieli; Paula Y Sacai; Solange R Salomão; Liang Shi Jung; Adriana Berezovsky
Journal:  Doc Ophthalmol       Date:  2019-07-08       Impact factor: 2.379

Review 7.  Ocular findings in a form of retinitis pigmentosa with a rhodopsin gene defect.

Authors:  E L Berson
Journal:  Trans Am Ophthalmol Soc       Date:  1990

8.  Do patients with age related maculopathy and cataract benefit from cataract surgery?

Authors:  G N Shuttleworth; E A Luhishi; R A Harrad
Journal:  Br J Ophthalmol       Date:  1998-06       Impact factor: 4.638

9.  A comparative study between the PAM and the laser interferometer in cataracts.

Authors:  M B Datiles; P A Edwards; M I Kaiser-Kupfer; L McCain; M Podgor
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1987       Impact factor: 3.117

10.  10-Hz flash visual evoked potentials predict post-cataract extraction visual acuity.

Authors:  J V Odom; R Hobson; J T Coldren; G M Chao; G W Weinstein
Journal:  Doc Ophthalmol       Date:  1987-08       Impact factor: 2.379

View more