Literature DB >> 1633747

Use of 10-Hz flash visual evoked potentials in prediction of final visual acuity in diabetic eyes with vitreous hemorrhage.

V L Vadrevu1, S Cavender, J V Odom.   

Abstract

In 44 diabetic eyes with vitreous hemorrhage, monocular steady-state visual evoked potentials were elicited through closed eyes by a 10-Hz flash. Visual evoked potentials were rated as normal or abnormal on the basis of amplitude and waveform. Abnormal visual evoked potentials were subdivided into mildly abnormal, markedly abnormal and nonrecordable categories. Patients with normal potentials were predicted to have visual acuities of 6/15 (20/50) or better. Patients with abnormal potentials were predicted to have visual acuities of 6/18 (20/60) or worse. Final visual acuities were the best visual acuities recorded in the 6 months after vitreous surgery (vitrectomy) or spontaneous clearing of the vitreous hemorrhage. The visual evoked potential categories and final acuities were compared with a 2 x 2 contingency table. The accuracy was 86%. The visual evoked potential categories and final acuities were associated at a statistically significant level.

Entities:  

Mesh:

Year:  1992        PMID: 1633747     DOI: 10.1007/bf00160950

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  21 in total

Review 1.  Prediction of postoperative vision in eyes with severe trauma.

Authors:  D G Fuller; W L Hutton
Journal:  Retina       Date:  1990       Impact factor: 4.256

2.  Analysis of the visual evoked response by Synchronous Detector techniques. I. Patients with cataracts.

Authors:  S J Fricker
Journal:  Invest Ophthalmol       Date:  1971-05

3.  Flash visual evoked potential as a prognostic factor for vitreous operations in diabetic eyes.

Authors:  E Scherfig; J Edmund; S Tinning; W Trojaborg
Journal:  Ophthalmology       Date:  1984-12       Impact factor: 12.079

4.  Prediction of post cataract extraction visual acuity: 10 Hz visually evoked potentials.

Authors:  J V Odom; G M Chao; R Hobson; G W Weinstein
Journal:  Ophthalmic Surg       Date:  1988-03

5.  Photocoagulation of the fovea.

Authors:  G W Weinstein; H G Rylander
Journal:  Trans Am Ophthalmol Soc       Date:  1978

6.  Limitations of blue field entoptoscopy in evaluating macular function.

Authors:  G E Murphy
Journal:  Ophthalmic Surg       Date:  1983-12

7.  Laser interferometric prediction of postoperative visual acuity in patients with cataracts.

Authors:  W Faulkner
Journal:  Am J Ophthalmol       Date:  1983-05       Impact factor: 5.258

8.  10-Hz flash visual evoked potentials predict post-cataract extraction visual acuity.

Authors:  J V Odom; R Hobson; J T Coldren; G M Chao; G W Weinstein
Journal:  Doc Ophthalmol       Date:  1987-08       Impact factor: 2.379

9.  Visual evoked potential as a prognostic factor for vitrectomy in diabetic eyes.

Authors:  E Scherfig; S Tinning; J Edmund; W Trojaborg
Journal:  Acta Ophthalmol (Copenh)       Date:  1983-10

10.  Clinical aspects of the visually evoked potential.

Authors:  G W Weinstein
Journal:  Trans Am Ophthalmol Soc       Date:  1977
View more
  4 in total

1.  Vitrectomy for traction macular detachment in diabetic retinopathy.

Authors:  P Meier; P Wiedemann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1997-09       Impact factor: 3.117

2.  Clinical heterogeneity of dominant optic atrophy: the contribution of visual function investigations to diagnosis.

Authors:  G Del Porto; E M Vingolo; K Steindl; R Forte; A Iannaccone; E Rispoli; M R Pannarale
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-12       Impact factor: 3.117

3.  Comparison of preoperative 10-Hz visual evoked potentials to contrast sensitivity and visual acuity after cataract extraction.

Authors:  S A Cavender; R R Hobson; G M Chao; G W Weinstein; J V Odom
Journal:  Doc Ophthalmol       Date:  1992       Impact factor: 2.379

Review 4.  Assessment of Human Visual Acuity Using Visual Evoked Potential: A Review.

Authors:  Xiaowei Zheng; Guanghua Xu; Kai Zhang; Renghao Liang; Wenqiang Yan; Peiyuan Tian; Yaguang Jia; Sicong Zhang; Chenghang Du
Journal:  Sensors (Basel)       Date:  2020-09-28       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.