Literature DB >> 3678858

A comparative study between the PAM and the laser interferometer in cataracts.

M B Datiles1, P A Edwards, M I Kaiser-Kupfer, L McCain, M Podgor.   

Abstract

We conducted a prospective study on 35 consecutive eyes undergoing cataract extraction to compare the Guyton-Minkowski Potential Acuity Meter (PAM) and the Laser Interferometer (LI) in determining potential visual acuity. The eyes were divided into: group A, which had good visualization of optic disc details, and group B, whose media allowed only disc outline or less to be seen. We found that in group A eyes, both instruments were reliable (with accuracies of 94% for the PAM and 88% for the LI). However, in group B eyes (advanced cataracts), both instruments were unreliable (accuracies of 33% for the PAM and 53% for the LI). Interestingly, in a subgroup of high myopes (axial length greater than 29 mm) with moderate cataracts and poor visual acuties, both instruments were very reliable and helpful in determining how much of the vision loss was due to the cataracts. We therefore strongly recommend potential acuity testing in high myopes with moderate cataracts and poor visual acuity.

Entities:  

Mesh:

Year:  1987        PMID: 3678858     DOI: 10.1007/bf02334176

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  8 in total

1.  Instruments for predicting visual acuity. A clinical comparison.

Authors:  R C Spurny; R Zaldivar; C D Belcher; R J Simmons
Journal:  Arch Ophthalmol       Date:  1986-02

2.  Misleading predictions of postoperative visual acuity.

Authors:  D L Guyton
Journal:  Arch Ophthalmol       Date:  1986-02

3.  Potential acuity meter for predicting postoperative visual acuity in cataract patients.

Authors:  J D Christenbury; S D McPherson
Journal:  Am J Ophthalmol       Date:  1985-03-15       Impact factor: 5.258

4.  Predicting acuities in capsulotomy patients: interferometers and potential acuity meter.

Authors:  W Faulkner
Journal:  J Am Intraocul Implant Soc       Date:  1983

5.  Potential acuity meter using a minute aerial pinhole aperture.

Authors:  J S Minkowski; M Palese; D L Guyton
Journal:  Ophthalmology       Date:  1983-11       Impact factor: 12.079

6.  Laser interferometric prediction of postoperative visual acuity in patients with cataracts.

Authors:  W Faulkner
Journal:  Am J Ophthalmol       Date:  1983-05       Impact factor: 5.258

7.  Retinal visual acuity in cataractous eyes. Determination with interference fringes.

Authors:  H Goldmann; A Chrenková; S Cornaro
Journal:  Arch Ophthalmol       Date:  1980-10

8.  Comparison of 2 interferometers for predicting visual acuity in patients with cataract.

Authors:  B L Halliday; J E Ross
Journal:  Br J Ophthalmol       Date:  1983-05       Impact factor: 4.638

  8 in total
  1 in total

1.  Longitudinal comparison of visual acuity as measured by the ETDRS chart and by the potential acuity meter in eyes with macular edema, and its relationship with retinal thickness and sensitivity.

Authors:  E Hatef; M Hanout; A Moradi; E Colantuoni; M Bittencourt; H Liu; Y J Sepah; M Ibrahim; D V Do; D L Guyton; Q D Nguyen
Journal:  Eye (Lond)       Date:  2014-08-08       Impact factor: 3.775

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.