Literature DB >> 6656692

Absorption and noise in cesium iodide x-ray image intensifiers.

J A Rowlands, K W Taylor.   

Abstract

The measured and theoretically predicted values of detective quantum efficiency (DQE) for a CsI x-ray image intensifier are compared for nine monoenergetic beams of x rays. The agreement between measurement and theory of better than +/- 5% indicates that we have a sound understanding of the physical parameters controlling the DQE. It is shown that the fraction of K-fluorescent x rays escaping from the input phosphor is independent of incident energy. The number of electrons released within the x-ray image intensifier (XRII) by an incident x ray has been measured. The mechanism for energy broadening within the XRII is shown to be predominantly the limited number of electrons and not light absorption.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6656692     DOI: 10.1118/1.595357

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  A method for the determination of the two-dimensional MTF of digital radiography systems using only the noise response.

Authors:  Andrew Kuhls-Gilcrist; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-03-23

2.  The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(TI) full-field flat panel detector.

Authors:  Ann-Katherine Carton; Raymond Acciavatti; Johnny Kuo; Andrew D A Maidment
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  Accurate MTF measurement in digital radiography using noise response.

Authors:  Andrew Kuhls-Gilcrist; Amit Jain; Daniel R Bednarek; Kenneth R Hoffmann; Stephen Rudin
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

4.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

Authors:  A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

5.  Theoretical and Monte Carlo optimization of a stacked three-layer flat-panel x-ray imager for applications in multi-spectral medical imaging.

Authors:  Sebastian Lopez Maurino; Aldo Badano; Ian A Cunningham; Karim S Karim
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-29

6.  Deriving depth-dependent light escape efficiency and optical Swank factor from measured pulse height spectra of scintillators.

Authors:  Adrian Howansky; Boyu Peng; Anthony R Lubinsky; Wei Zhao
Journal:  Med Phys       Date:  2017-02-13       Impact factor: 4.071

7.  Morphologically controlled synthesis of ionic cesium iodide colloidal nanocrystals and electron beam-induced transformations.

Authors:  Weidong Song; Xiaotong Wu; Qian Di; Tianjiao Xue; Jichao Zhu; Zewei Quan
Journal:  RSC Adv       Date:  2018-05-22       Impact factor: 4.036

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.