Literature DB >> 6655069

Measurement of the enzymes lactate dehydrogenase and creatine kinase using reflectance spectroscopy and reagent strips.

J F Stevens, W Tsang, R G Newall.   

Abstract

Two new methods for the assay of total activities of lactate dehydrogenase and creatine kinase are described, in which the enzyme activities are measured from a solid-state reagent strip during a kinetic reaction, the reaction being monitored in the ultra-violet region of the spectrum by reflectance spectroscopy. The performances of these methods are evaluated, and compared to conventional "wet" chemistry methods. The solid-phase reagent methods demonstrated precision and accuracy acceptable for diagnostic purposes, and were easy to use by trained operators.

Mesh:

Substances:

Year:  1983        PMID: 6655069      PMCID: PMC498571          DOI: 10.1136/jcp.36.12.1371

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  5 in total

1.  Creatine kinase in serum: 1. Determination of optimum reaction conditions.

Authors:  G Szasz; W Gruber; E Bernt
Journal:  Clin Chem       Date:  1976-05       Impact factor: 8.327

2.  A spectrophotometric method for the determination of creatine phosphokinase and myokinase.

Authors:  I T OLIVER
Journal:  Biochem J       Date:  1955-09       Impact factor: 3.857

3.  An improved procedure for serum creatine phosphokinase determination.

Authors:  S B Rosalki
Journal:  J Lab Clin Med       Date:  1967-04

4.  Application of reflectance spectroscopy to the estimation of uric acid, urea and glucose: an evaluation of the Ames Seralyzer.

Authors:  J F Stevens; R G Newall
Journal:  J Clin Pathol       Date:  1983-01       Impact factor: 3.411

5.  [Determination of blood constituents with dry reagent carriers. Comparison with wet chemical tests (author's transl)].

Authors:  L Thomas; W Appel; G Storz; W Plischke
Journal:  Dtsch Med Wochenschr       Date:  1981-08-28       Impact factor: 0.628

  5 in total
  2 in total

1.  Measurement of creatine kinase by reflectance spectroscopy and reagent strips--effect of EDTA.

Authors:  J F Stevens
Journal:  J Clin Pathol       Date:  1984-05       Impact factor: 3.411

2.  Rapid measurement of creatine kinase activity in a coronary care unit using a portable benchtop reflectance photometer.

Authors:  I Gibb; J R Barton; P C Adams; D Pratt; C R Dean; I F Tarbit
Journal:  Br Med J (Clin Res Ed)       Date:  1985-05-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.