A simple method of measuring total respiratory system compliance in newborn infants.

A Olinsky, A C Bryan, M H Bryan.   

Abstract

A new method of measuring the static compliance of the respiratory system in the awake, non-paralysed infant is described. The static compliance was measured by this method in 12 healthy premature infants aged from 1 day to 30 weeks. In addition, the dynamic compliance was measured by the oesophageal balloon technique. The static compliance was significantly higher than the dynamic, and this difference was related to the respiratory rate. These infants therefore demonstrated frequency dependence of dynamic compliance.

Entities:  

Mesh:

Year:  1976        PMID: 1251289

Source DB:  PubMed          Journal:  S Afr Med J


  8 in total

1.  Respiratory compliance in premature babies treated with artificial surfactant (ALEC).

Authors:  C J Morley; A Greenough
Journal:  Arch Dis Child       Date:  1991-04       Impact factor: 3.791

2.  Disturbance in respiratory mechanics in infants with bronchiolitis.

Authors:  J Seidenberg; I B Masters; I Hudson; A Olinsky; P D Phelan
Journal:  Thorax       Date:  1989-08       Impact factor: 9.139

3.  Ventilator settings for newborn infants.

Authors:  C A Ramsden; E O Reynolds
Journal:  Arch Dis Child       Date:  1987-05       Impact factor: 3.791

4.  Pulmonary compliance in sick low birthweight infants. How reliable is the measurement of oesophageal pressure?

Authors:  A Thomson; J Elliott; M Silverman
Journal:  Arch Dis Child       Date:  1983-11       Impact factor: 3.791

5.  Static respiratory compliance in the newborn. I: A clinical and prognostic index for mechanically ventilated infants.

Authors:  W O Tarnow-Mordi; R A Wilkie; E Reid
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-01       Impact factor: 5.747

6.  Comparison of chest radiography and static respiratory compliance in the assessment of the severity of pulmonary diseases in newborns with respiratory distress.

Authors:  A Lischka; H Coradello; G Simbruner; C Popow; A Pollak
Journal:  Pediatr Radiol       Date:  1984

7.  Reliability of clinical assessments of respiratory system compliance (Crs) made by junior doctors.

Authors:  B J Stenson; R A Wilkie; I A Laing; W O Tarnow-Mordi
Journal:  Intensive Care Med       Date:  1995-03       Impact factor: 17.440

Review 8.  Infant lung function testing in the intensive care unit.

Authors:  J Hammer; C J Newth
Journal:  Intensive Care Med       Date:  1995-09       Impact factor: 17.440

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.