Literature DB >> 6630468

Evaluation of four gentamicin and tobramycin assay procedures for clinical laboratories.

F G Witebsky, C A Sliva, S T Selepak, M E Ruddel, J D MacLowry, E E Johnson, R J Elin.   

Abstract

Accuracy, precision, and clinical laboratory utility of the TDX (Abbott Laboratories), Auto-ICS (Beckman Instruments, Inc.), COBAS-Bio (Roche Analytical Instruments, Inc.) with reagent kits (Syva), and EMIT (Syva) for gentamicin and tobramycin serum assay were assessed. TDX, COBAS-Bio, and EMIT analytical systems showed a proportional bias of less than 10% for recovery studies and a coefficient of variation less than 5% for within-run precision. The results of the recovery studies with the Auto-ICS showed a proportional bias of 25% with gentamicin and 16% with tobramycin. The within-run precision expressed as the coefficient of variation for the Auto-ICS was 6.7% for gentamicin and 8.6% for tobramycin. In comparisons involving gentamicin- and tobramycin-containing patient samples, the results with the TDX analytical system showed the best agreement with the COBAS-Bio. For the determination of these two antibiotics, the TDX analytical system provided the best overall accuracy and precision.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6630468      PMCID: PMC270925          DOI: 10.1128/jcm.18.4.890-894.1983

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  Incorrect least-squares regression coefficients in method-comparison analysis.

Authors:  P J Cornbleet; N Gochman
Journal:  Clin Chem       Date:  1979-03       Impact factor: 8.327

2.  Radioimmunoassay, acetylating radio-enzymatic assay, and microbioassay of gentamicin: a comparative study.

Authors:  P Stevens; L S Young; W L Hewitt
Journal:  J Lab Clin Med       Date:  1975-08

3.  Comparative evaluation of three methods for measuring gentamicin and tobramycin in serum.

Authors:  J H Ngui-Yen; T Hofmann; M Wigmore; J A Smith
Journal:  Antimicrob Agents Chemother       Date:  1981-12       Impact factor: 5.191

4.  Evaluation of five gentamicin assay procedures for clinical microbiology laboratories.

Authors:  S T Selepak; F G Witebsky; E A Robertson; J D MacLowry
Journal:  J Clin Microbiol       Date:  1981-04       Impact factor: 5.948

5.  Evaluation of serum gentamicin assay procedures for a clinical microbiology laboratory.

Authors:  C H Lantz; D J Lawrie; F G Witebsky; J D MacLowry
Journal:  J Clin Microbiol       Date:  1980-10       Impact factor: 5.948

  5 in total
  2 in total

1.  Comparison of the Beckman Auto ICS and the Syva Autolab 6000 for determination of gentamicin levels in serum.

Authors:  R H Glew; R A Pavuk
Journal:  J Clin Microbiol       Date:  1985-01       Impact factor: 5.948

2.  Comparison of enzyme-multiplied immunoassay technique with fluorescence polarization immunoassay for determination of gentamicin and tobramycin levels in serum.

Authors:  D J Pohlod; L D Saravolatz; M M Somerville
Journal:  J Clin Microbiol       Date:  1984-11       Impact factor: 5.948

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.