Single-position calibration of the respiratory inductance plethysmograph.

B Loveridge, P West, N R Anthonisen, M H Kryger.   

Abstract

Since we intended to use the respiratory inductance plethysmograph (RIP) to study breathing patterns in a single body position, we developed a method to calibrate the RIP in one position (seated) and verified the stability of this calibration procedure during a 60-min period. The subject breathed spontaneously through a pneumotachograph for 1 min during all calibration and verification runs. All inspiratory data from the abdomen and rib cage RIP transducers was analyzed using multiple linear regression analysis to calculate calibration factors for the transducers. Eight normal subjects were studied, and the stability of calibration at 20, 40, and 60 min was determined. The correlation coefficients were all greater than 0.94. The mean slope and mean intercept describing the relationship of the RIP volume to the pneumotachograph volume for all calibration and verification runs were 0.995 +/- 0.074 and 0.012 +/- 0.018 liter, respectively. This calibration method allows a spirogram to be generated from the RIP signals. Therefore, this technique may be valuable in further investigating resting breathing patterns in humans.

Entities:  

Mesh:

Year:  1983        PMID: 6629900     DOI: 10.1152/jappl.1983.55.3.1031

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  9 in total

1.  Error analysis of a natural breathing calibration method for respiratory inductive plethysmography.

Authors:  N O Strömberg
Journal:  Med Biol Eng Comput       Date:  2001-05       Impact factor: 2.602

Review 2.  Breathing pattern analysis.

Authors:  M J Tobin
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

3.  Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography.

Authors:  Wai Leung Ambrose Lo; Dong Feng Huang
Journal:  J Clin Monit Comput       Date:  2016-06-11       Impact factor: 2.502

4.  Improved regression models for ventilation estimation based on chest and abdomen movements.

Authors:  Shaopeng Liu; Robert Gao; Qingbo He; John Staudenmayer; Patty Freedson
Journal:  Physiol Meas       Date:  2012-01       Impact factor: 2.833

5.  Correlation of ultrasound imaging of oral swallow with ventilatory alterations in cerebral palsied and normal children: preliminary observations.

Authors:  D J Kenny; M J Casas; K A McPherson
Journal:  Dysphagia       Date:  1989       Impact factor: 3.438

6.  Computerized artifact detection for ventilatory inductance plethysmographic apnea monitors.

Authors:  K A East; T D East; V J Mathews; B T Waterfall
Journal:  J Clin Monit       Date:  1989-07

7.  Swallowing/ventilation interactions during oral swallow in normal children and children with cerebral palsy.

Authors:  M J Casas; D J Kenny; K A McPherson
Journal:  Dysphagia       Date:  1994       Impact factor: 3.438

8.  Reducing the airflow waveform distortions from breathing style and body position with improved calibration of respiratory effort belts.

Authors:  Tiina M Seppänen; Olli-Pekka Alho; Tapio Seppänen
Journal:  Biomed Eng Online       Date:  2013-09-28       Impact factor: 2.819

9.  Respiration rate and volume measurements using wearable strain sensors.

Authors:  Michael Chu; Thao Nguyen; Vaibhav Pandey; Yongxiao Zhou; Hoang N Pham; Ronen Bar-Yoseph; Shlomit Radom-Aizik; Ramesh Jain; Dan M Cooper; Michelle Khine
Journal:  NPJ Digit Med       Date:  2019-02-13
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.