Abstract

Iterative algorithms have been investigated for reconstructing images from data acquired with a new type of gamma camera based upon an electronic method of collimating gamma radiation. The camera is composed of two detection systems which record a sequential interaction of the emitted gamma radiation. Coincident counting in accordance with Compton scattering kinematics leads to a localization of activity upon a multitude of conical surfaces throughout the object. A two-stage reconstruction procedure in which conical line projection images as seen by each position sensing element of the first detector are reconstructed in the first stage, and tomographic images are reconstructed in the second stage, has been developed. Computer simulation studies of both stages and first-stage reconstruction studies with preliminary experimental data are reported. Experimental data were obtained with one detection element of a prototype germanium detector. A microcomputer based circuit was developed to record coincident counts between the germanium detector and an uncollimated conventional scintillation camera. Point sources of Tc-99m and Cs-137 were used to perform preliminary measurements of sensitivity and point spread function characteristics of electronic collimation.

Entities:  

Mesh:

Year:  1983        PMID: 6604217     DOI: 10.1118/1.595314

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Is PET the future of nuclear medicine?

Authors:  Dale L Bailey
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-06-17       Impact factor: 9.236

Review 2.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

3.  Representation of photon limited data in emission tomography using origin ensembles.

Authors:  A Sitek
Journal:  Phys Med Biol       Date:  2008-05-27       Impact factor: 3.609

4.  Resolution recovery for Compton camera using origin ensemble algorithm.

Authors:  A Andreyev; A Celler; I Ozsahin; A Sitek
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

5.  Compton scatter imaging: A promising modality for image guidance in lung stereotactic body radiation therapy.

Authors:  Gage Redler; Kevin C Jones; Alistair Templeton; Damian Bernard; Julius Turian; James C H Chu
Journal:  Med Phys       Date:  2018-02-07       Impact factor: 4.071

6.  A maximum NEC criterion for Compton collimation to accurately identify true coincidences in PET.

Authors:  Garry Chinn; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2011-02-10       Impact factor: 10.048

7.  Reconstruction of emission tomography data using origin ensembles.

Authors:  Arkadiusz Sitek
Journal:  IEEE Trans Med Imaging       Date:  2010-12-10       Impact factor: 10.048

Review 8.  Compton imaging for medical applications.

Authors:  Hideaki Tashima; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2022-07-22

Review 9.  Development and Applications of Compton Camera-A Review.

Authors:  Raj Kumar Parajuli; Makoto Sakai; Ramila Parajuli; Mutsumi Tashiro
Journal:  Sensors (Basel)       Date:  2022-09-28       Impact factor: 3.847

10.  The Mathematical Foundations of 3D Compton Scatter Emission Imaging.

Authors:  T T Truong; M K Nguyen; H Zaidi
Journal:  Int J Biomed Imaging       Date:  2007
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.