Literature DB >> 6546768

Superior intensity and reproducibility of SHU-454, a new right heart contrast agent.

M D Smith, O L Kwan, H J Reiser, A N DeMaria.   

Abstract

Intravenous injection of a variety of fluids has been shown to produce right heart contrast by ultrasound, but the intensity and reproducibility achieved are variable. Thus, a new polysaccharide agent being developed for commercial distribution, SHU-454, was quantitatively compared for intensity and variability with agitated saline solution, indocyanine green, carbon dioxide and hydrogen peroxide. Videodensitometry was used to measure peak and total opacification of the right ventricle after peripheral intravenous contrast administration. One hundred eighty injections were performed in nine closed chest dogs while two-dimensional echograms were recorded. SHU-454 yielded the highest peak (p less than 0.001) and total (p less than 0.005) intensity values when compared with the standard agents. In addition, SHU-454 yielded the lowest coefficient of variation between injections (p less than 0.04) in producing this contrast effect. There were no biologically significant changes in heart rate, blood pressure or arterial blood gases during injection of any of the substances used. A newly developed agent, SHU-454, is superior to standard agents in the ability to reliably produce right heart contrast after venous injection in dogs.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6546768     DOI: 10.1016/s0735-1097(84)80358-7

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  9 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  Flow quantitation by contrast echocardiography. Effects of intervening tissue and of the angle of incidence between flow and ultrasonic beam.

Authors:  D Rovai; M Lombardi; L Taddei; A Mazzarisi; L Landini; G Ghelardini; A Distante; A Benassi; A L'Abbate
Journal:  Int J Card Imaging       Date:  1993-03

6.  Vaginal axis after abdominal, vaginal and laparoscopic hysterectomy: a preliminary study with perineal ultrasonography using contrast medium.

Authors:  H S Virtanen; J I Mäkinen; M A Haarala; P J Kiilholma
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  1996

7.  Flow quantitation by radio frequency analysis of contrast echocardiography.

Authors:  D Rovai; M Lombardi; A Mazzarisi; L Landini; L Taddei; A Distante; A Benassi; A L'Abbate
Journal:  Int J Card Imaging       Date:  1993-03

8.  Air-filled proteinaceous microbubbles: synthesis of an echo-contrast agent.

Authors:  M W Grinstaff; K S Suslick
Journal:  Proc Natl Acad Sci U S A       Date:  1991-09-01       Impact factor: 11.205

9.  Immunological evaluation of the new stable ultrasound contrast agent LK565: a phase one clinical trial.

Authors:  B Funke; H K Maerz; S Okorokow; S Polata; I Lehmann; U Sack; P Wild; T Geisler; R J Zotz
Journal:  Cardiovasc Ultrasound       Date:  2004-09-10       Impact factor: 2.062

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.