Literature DB >> 6544798

Property changes of UHMW polyethylene hip cup endoprostheses during implantation.

P Eyerer, Y C Ke.   

Abstract

In this study it is demonstrated that the combined chemical and mechanical influences of the implant situation cause property changes of ultra-high-molecular-weight polyethylene (UHMW PE) hip joint cups. Nearly 30 out of 48 loosened cups, retrieved 3 weeks to 11 years after implantation, were investigated. Density measurements show a density increase with implantation time and a dependence of these changes from implant position and loading conditions. The rate of extractable constituents also increases with course of time. An increased in vivo conditioned oxidation of the UHMW PE can be demonstrated by infrared (IR) spectrometry. The density increase can be explained by post-crystallization, which is the result of oxidative chain scission. This leads to a reduction of the average molecular weight of the PE and to an increased extractability of constituents. Since these changes have been recognized as the reasons for aging and failing of UHMW PE, the methods of material characterization used in this study for retrieved implants will help to develop suitable in vitro testing and simulating methods. They are the prerequisite for the necessary improvements of the material properties of UHMW PE.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6544798     DOI: 10.1002/jbm.820180915

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  5 in total

1.  Comparison of the wear of aged and non-aged ultrahigh molecular weight polyethylene sterilized by gamma irradiation and by gas plasma.

Authors:  J Fisher; E A Reeves; G H Isaac; K A Saum; W M Sanford
Journal:  J Mater Sci Mater Med       Date:  1997-06       Impact factor: 3.896

2.  Highly cross-linked ultrahigh molecular weight polyethylene with improved fatigue resistance for total joint arthroplasty: recipient of the 2006 Hap Paul Award.

Authors:  Ebru Oral; Arnaz S Malhi; Keith K Wannomae; Orhun K Muratoglu
Journal:  J Arthroplasty       Date:  2008-06-10       Impact factor: 4.757

3.  Gamma inert sterilization: a solution to polyethylene oxidation?

Authors:  Francisco J Medel; Steven M Kurtz; William J Hozack; Javad Parvizi; James J Purtill; Peter F Sharkey; Daniel MacDonald; Matthew J Kraay; Victor Goldberg; Clare M Rimnac
Journal:  J Bone Joint Surg Am       Date:  2009-04       Impact factor: 5.284

4.  On the assessment of oxidative and microstructural changes after in vivo degradation of historical UHMWPE knee components by means of vibrational spectroscopies and nanoindentation.

Authors:  Francisco J Medel; Clare M Rimnac; Steven M Kurtz
Journal:  J Biomed Mater Res A       Date:  2009-05       Impact factor: 4.396

5.  Histological results with cement-free implanted hip joint sockets of polyethylene.

Authors:  P Eyerer
Journal:  Arch Orthop Trauma Surg       Date:  1985
  5 in total