Literature DB >> 6544792

The fatigue strength of porous-coated Ti-6%Al-4%V implant alloy.

S Yue, R M Pilliar, G C Weatherly.   

Abstract

The fatigue behaviour of Ti-6Al-4V (extra low interstital) alloy coated with Ti-6Al-4V powder was investigated using rotating bending fatigue testing. It was found that the high cycle fatigue strength of porous coated specimens exhibited a substantial decrease compared to uncoated specimens of the same microstructure. Chemical analysis of the sintered surface revealed significant increases of interstitials compared to the bulk analysis, but it is concluded that this would not adversely affect the fatigue strength. Scanning electron microscopy revealed crack initiation close to particle/substrate contact interfaces and it is concluded that stress intensification due to these interface regions are major sources of weakness with respect to fatigue strength. Finally it was found that subjecting a polished Ti-6Al-4V specimen to the heat treatment required for sintering resulted in delineation of prior beta grain boundaries and it is suggested that this also contributes to the inferior fatigue strength of porous coated Ti-6Al-4V.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6544792     DOI: 10.1002/jbm.820180908

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  12 in total

1.  Effect of passivation on the dissolution behavior of Ti6A14V and vacuum-brazed Ti6A14V in Hank's ethylene diamine tetra-acetic acid solution Part I Ion release.

Authors:  T M Lee; E Chang; C Y Yang
Journal:  J Mater Sci Mater Med       Date:  1999-09       Impact factor: 3.896

2.  A comparison of the corrosion behaviour and surface characteristics of vacuum-brazed and heat-treated Ti6Al4V alloy.

Authors:  T M Lee; E Chang; C Y Yang
Journal:  J Mater Sci Mater Med       Date:  1998-08       Impact factor: 3.896

3.  Effect of passivation and surface modification on the dissolution behavior and nano-surface characteristics of Ti-6Al-4V in Hank/EDTA solution.

Authors:  T M Lee
Journal:  J Mater Sci Mater Med       Date:  2006-01       Impact factor: 3.896

4.  Effect of the oxygen content in solution on the static and cyclic deformation of titanium foams.

Authors:  L P Lefebvre; E Baril; M N Bureau
Journal:  J Mater Sci Mater Med       Date:  2009-06-25       Impact factor: 3.896

5.  Quasi-static Torsional Deformation Behavior of Porous Ti6Al4V alloy.

Authors:  Vamsi Krishna Balla; Shantel Martinez; Ben Tunberg Rogoza; Chase Livingston; Deepak Venkateswaran; Susmita Bose; Amit Bandyopadhyay
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2011-07-20       Impact factor: 7.328

6.  Characterization of surface modified Ti-6Al-7Nb alloy.

Authors:  S Spriano; M Bronzoni; E Vernè; G Maina; V Bergo; M Windler
Journal:  J Mater Sci Mater Med       Date:  2005-04       Impact factor: 3.896

7.  In Vivo Response of Laser Processed Porous Titanium Implants for Load-Bearing Implants.

Authors:  Amit Bandyopadhyay; Anish Shivaram; Solaiman Tarafder; Himanshu Sahasrabudhe; Dishary Banerjee; Susmita Bose
Journal:  Ann Biomed Eng       Date:  2016-06-15       Impact factor: 3.934

8.  Direct laser processing of a tantalum coating on titanium for bone replacement structures.

Authors:  Vamsi Krishna Balla; Shashwat Banerjee; Susmita Bose; Amit Bandyopadhyay
Journal:  Acta Biomater       Date:  2009-12-04       Impact factor: 8.947

9.  Surface characteristics of Ti6Al4V alloy: effect of materials, passivation and autoclaving.

Authors:  T M Lee; E Chang; C Y Yang
Journal:  J Mater Sci Mater Med       Date:  1998-08       Impact factor: 3.896

10.  Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants.

Authors:  Amit Bandyopadhyay; Felix Espana; Vamsi Krishna Balla; Susmita Bose; Yusuke Ohgami; Neal M Davies
Journal:  Acta Biomater       Date:  2009-11-12       Impact factor: 8.947

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.