Literature DB >> 15348855

A comparison of the corrosion behaviour and surface characteristics of vacuum-brazed and heat-treated Ti6Al4V alloy.

T M Lee1, E Chang, C Y Yang.   

Abstract

The corrosion characteristics of the brazed Ti6Al4V specimens were analysed and compared with respect to the conventionally heat-treated specimens by an electrochemical corrosion test. The object of this research was to explore the potentiality of the brazed titanium for biomaterials. The characteristics of the 1300 degrees C heat-treated and the 970 degrees C brazed specimens, with passivation and sterilization treatment, were evaluated by measurement of corrosion potential, Ecorr, corrosion current densities, Icorr, polarization resistance of the reacted surface films, Rp, in a potentiodynamic test. The experimental results show that the corrosion rates of the heat-treated and the brazed samples are similar at Ecorr, and the value of Ecorr for the brazed sample is noble to the heat-treated samples. The passive current density of the brazed specimen is either lower or higher than the heat-treated specimen, depending on the polarization potential. By Auger electron spectroscopic and high-resolution X-ray photoelectron spectroscopic analysis on specimens from the potentiostatic test, the elements of copper and nickel in the brazing filler were not detected while less alumina was found in the reacted film of the brazed specimens when compared with the heat-treated specimens. The implication of the results is discussed.

Entities:  

Year:  1998        PMID: 15348855     DOI: 10.1023/a:1008863232494

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  7 in total

1.  In vivo measurement of anodic polarization of orthopaedic implant alloys: comparative study of in vivo and in vitro experiments.

Authors:  Y Nakayama; T Yamamuro; Y Kotoura; M Oka
Journal:  Biomaterials       Date:  1989-08       Impact factor: 12.479

2.  Dental implant materials. II. Preparative procedures and surface spectroscopic studies.

Authors:  D C Smith; R M Pilliar; J B Metson; N S McIntyre
Journal:  J Biomed Mater Res       Date:  1991-09

3.  Dental implant materials. I. Some effects of preparative procedures on surface topography.

Authors:  D C Smith; R M Pilliar; R Chernecky
Journal:  J Biomed Mater Res       Date:  1991-09

4.  The effect of post-sintering heat treatments on the fatigue properties of porous coated Ti-6Al-4V alloy.

Authors:  S D Cook; N Thongpreda; R C Anderson; R J Haddad
Journal:  J Biomed Mater Res       Date:  1988-04

5.  The fatigue strength of porous-coated Ti-6%Al-4%V implant alloy.

Authors:  S Yue; R M Pilliar; G C Weatherly
Journal:  J Biomed Mater Res       Date:  1984 Nov-Dec

6.  Fatigue properties of carbon- and porous-coated Ti-6Al-4V alloy.

Authors:  S D Cook; F S Georgette; H B Skinner; R J Haddad
Journal:  J Biomed Mater Res       Date:  1984 May-Jun

7.  The mechanisms of passive dissolution of titanium in a model physiological environment.

Authors:  K E Healy; P Ducheyne
Journal:  J Biomed Mater Res       Date:  1992-03
  7 in total
  2 in total

1.  Effect of passivation and surface modification on the dissolution behavior and nano-surface characteristics of Ti-6Al-4V in Hank/EDTA solution.

Authors:  T M Lee
Journal:  J Mater Sci Mater Med       Date:  2006-01       Impact factor: 3.896

2.  Surface characteristics of Ti6Al4V alloy: effect of materials, passivation and autoclaving.

Authors:  T M Lee; E Chang; C Y Yang
Journal:  J Mater Sci Mater Med       Date:  1998-08       Impact factor: 3.896

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.