Literature DB >> 1997977

Cardiac output by pulsed Doppler in neonates using the apical window.

V H Mandelbaum-Isken1, O Linderkamp.   

Abstract

In 18 healthy neonates, cardiac output was measured by range-gated Doppler echocardiography with simultaneous two-dimensional echocardiography, using the apical approach. Maximal and modal flow velocities were compared by using spectral analysis of the Doppler signal. Blood flow velocities were measured in the left ventricular outflow tract and in the ascending aorta. Cardiac index (cardiac output per kg body weight), with the sample volume placed in the left ventricular outflow, averaged 170 +/- 45 ml/min/kg in the maximal flow velocity mode and 133 +/- 39 ml/min/kg in the modal mode, respectively (p less than 0.05). Sampling in the ascending aorta gave cardiac index values of 198 +/- 73 ml/min/kg in the maximal velocity and 167 +/- 58 ml/min/kg in the modal velocity mode. Maximal flow velocities in the ascending aorta came closest to published data obtained by invasive and noninvasive methods.

Mesh:

Year:  1991        PMID: 1997977     DOI: 10.1007/BF02238491

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  14 in total

1.  Pulsed Doppler determinations of cardiac output in neonates: normal standards for clinical use.

Authors:  F J Walther; B Siassi; N A Ramadan; A K Ananda; P Y Wu
Journal:  Pediatrics       Date:  1985-11       Impact factor: 7.124

2.  Cardiac output in newborn infants.

Authors:  G C Emmanouilides; A J Moss; M Monset-Couchard; B A Marcano; B Rzeznic
Journal:  Biol Neonate       Date:  1970

3.  Hemodynamic adaptations in the newborn infant.

Authors:  I Gessner; L J Krovetz; R W Benson; H Prystowsky; V Stenger; D V Eitzman
Journal:  Pediatrics       Date:  1965-11       Impact factor: 7.124

4.  A pulsed Doppler echocardiographic study of the postnatal changes in pulmonary artery and ascending aortic flow in normal term newborn infants.

Authors:  K Takenaka; F Waffarn; A Dabestani; J M Gardin; W L Henry
Journal:  Am Heart J       Date:  1987-03       Impact factor: 4.749

5.  Reproducibility of Doppler aortic blood flow measurements: studies on intraobserver, interobserver and day-to-day variability in normal subjects.

Authors:  J M Gardin; A Dabestani; K Matin; A Allfie; D Russell; W L Henry
Journal:  Am J Cardiol       Date:  1984-11-01       Impact factor: 2.778

6.  Determination of cardiac output by Doppler echocardiography.

Authors:  H Ihlen; J P Amlie; J Dale; K Forfang; S Nitter-Hauge; J E Otterstad; S Simonsen; E Myhre
Journal:  Br Heart J       Date:  1984-01

7.  Cardiac output in newborn infants with transient myocardial dysfunction.

Authors:  F J Walther; B Siassi; N A Ramadan; P Y Wu
Journal:  J Pediatr       Date:  1985-11       Impact factor: 4.406

8.  Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.

Authors:  D J Sahn; A DeMaria; J Kisslo; A Weyman
Journal:  Circulation       Date:  1978-12       Impact factor: 29.690

9.  Effect of booster blood transfusions on oxygen utilization in infants with bronchopulmonary dysplasia.

Authors:  D C Alverson; V H Isken; R S Cohen
Journal:  J Pediatr       Date:  1988-10       Impact factor: 4.406

10.  Noninvasive measurement of cardiac output in healthy preterm and term newborn infants.

Authors:  D C Alverson; M W Eldridge; J D Johnson; M Aldrich; P Angelus; W Berman
Journal:  Am J Perinatol       Date:  1984-01       Impact factor: 1.862

View more
  8 in total

1.  Severity of the ductal shunt: a comparison of different markers.

Authors:  M El Hajjar; G Vaksmann; T Rakza; G Kongolo; L Storme
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2005-09       Impact factor: 5.747

2.  Assessment of cardiac function in infants with transposition of the great arteries after surgery: comparison of two methods.

Authors:  Fan Yang; Roberta Iacobelli; Jian-Ming Wang; Fiore Salvatore Iorio
Journal:  World J Pediatr       Date:  2018-07-30       Impact factor: 2.764

3.  Early determinants of right and left ventricular output in ventilated preterm infants.

Authors:  N Evans; M Kluckow
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-03       Impact factor: 5.747

4.  Range of echocardiographic findings in term neonates with high oxygen requirements.

Authors:  N Evans; M Kluckow; A Currie
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1998-03       Impact factor: 5.747

Review 5.  Diagnosis of patent ductus arteriosus in the preterm newborn.

Authors:  N Evans
Journal:  Arch Dis Child       Date:  1993-01       Impact factor: 3.791

6.  Effects of red cell transfusion on cardiac output and blood flow velocities in cerebral and gastrointestinal arteries in premature infants.

Authors:  M Nelle; C Höcker; E P Zilow; O Linderkamp
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-07       Impact factor: 5.747

7.  The methodology of Doppler-derived central blood flow measurements in newborn infants.

Authors:  Koert A de Waal
Journal:  Int J Pediatr       Date:  2012-01-16

8.  Assessment and feasibility of the four landmarks of the aortic root in a cohort of very preterm infants.

Authors:  Sam Phillips; Koert A de Waal
Journal:  Ann Pediatr Cardiol       Date:  2015 Sep-Dec
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.