Literature DB >> 6501534

Specificity and sensitivity of the IgM capture immunoassay: studies of possible factors inducing false positive or false negative results.

M J Briantais, L Grangeot-Keros, J Pillot.   

Abstract

The specificity and sensitivity of the IgM-capture immunoassay (IgM-CI) were evaluated for detection of rubella specific IgM and hepatitis B core (HBc) specific IgM. For rubella specific IgM, antibodies bound to the solid phase were detected by haemadsorption and for HBc specific IgM, by using HBc antigen (HBcAg) and radiolabelled IgG anti-HBc. Rheumatoid factor (RF) was found to interfere in the test for HBc specific IgM because IgM-RF bound to the solid phase reacted with aggregated radiolabelled HBc specific IgG. This false positive reaction did not occur when radiolabelled F(ab')2 was used instead of the whole IgG molecule. HBcAg purified from biological fluids might be coated with host IgG and under these conditions, HBcAg could react with RF. It was also demonstrated that high levels of IgG antibodies could interfere with IgG anti-mu coated-surface by means of non-immunological protein-protein interactions. In fact, IgG did not interfere in the rubella assay, whereas it did in the very sensitive anti-HBc test. To prevent this false-positive reaction, different dilution media were tested. Only the addition of non-specific IgG and fetal calf serum (FCS), to the dilution medium, seems to improve the specificity of the test. Furthermore, in order to decrease this non-specific IgG-IgG interaction and an occasional prozoning phenomenon, the dilution of serum to be tested was taken into account. Parameters considered to decrease sensitivity were also studied. RF, anti-F(ab')2 antibodies and non-specific IgM did not decrease significantly the sensitivity of the assay.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6501534     DOI: 10.1016/0166-0934(84)90079-x

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  12 in total

1.  Improvement of immunoglobulin M capture immunoassay specificity: toxoplasma antibody detection method as a model.

Authors:  T Tuuminen; H Seppänen; E M Pitkänen; P Palomäki; K Käpyaho
Journal:  J Clin Microbiol       Date:  1999-01       Impact factor: 5.948

2.  Comparison of six commercial enzyme linked immunosorbent assays for detecting IgM antibodies against Toxoplasma gondii.

Authors:  C Verhofstede; L Van Renterghem; J Plum
Journal:  J Clin Pathol       Date:  1989-12       Impact factor: 3.411

3.  Experimental transmission of the delta virus to a hepatitis B chronic carrier chimpanzee with the development of persistent delta carriage.

Authors:  H A Fields; S Govindarajan; H S Margolis; C D Schable; J W Ebert; J E Maynard
Journal:  Am J Pathol       Date:  1986-02       Impact factor: 4.307

4.  Evaluation of immunoblotting for the detection of Toxoplasma gondii immunoglobulin M antibodies.

Authors:  C Verhofstede; L Van Renterghem; J Plum
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1990-11       Impact factor: 3.267

5.  Development of a highly specific and sensitive rubella immunoglobulin M antibody capture enzyme immunoassay that uses enzyme-labeled antigen.

Authors:  H Seppänen
Journal:  J Clin Microbiol       Date:  1990-04       Impact factor: 5.948

6.  Comparison of a new immunochromatographic test to enzyme-linked immunosorbent assay for rapid detection of immunoglobulin m antibodies to hepatitis e virus in human sera.

Authors:  Hsiao Ying Chen; Yang Lu; Teresa Howard; David Anderson; Priscilla Yiquan Fong; Wei-Ping Hu; Chee Poh Chia; Ming Guan
Journal:  Clin Diagn Lab Immunol       Date:  2005-05

7.  Indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assays (ELISAs) and IgM capture ELISA for detection of antibodies to lipopolysaccharide in adult typhoid fever patients in Pakistan.

Authors:  J Sippel; N Bukhtiari; M B Awan; R Krieg; J F Duncan; K A Karamat; I A Malik; L M Igbal; L Legters
Journal:  J Clin Microbiol       Date:  1989-06       Impact factor: 5.948

8.  Cutoff levels of immunoglobulin M antibody against viral core antigen for differentiation of acute, chronic, and past hepatitis B virus infections.

Authors:  W H Gerlich; A Uy; F Lambrecht; R Thomssen
Journal:  J Clin Microbiol       Date:  1986-08       Impact factor: 5.948

9.  Double-antigen enzyme-linked immunosorbent assay for detection of hepatitis E virus-specific antibodies in human or swine sera.

Authors:  Wei Ping Hu; Yang Lu; Nestor Amadeo Precioso; Hsiao Ying Chen; Teresa Howard; David Anderson; Ming Guan
Journal:  Clin Vaccine Immunol       Date:  2008-05-21

10.  Prevalence and clinical significance of circulating autoantibodies in idiopathic pulmonary fibrosis.

Authors:  Joyce S Lee; Eunice J Kim; Kara L Lynch; Brett Elicker; Christopher J Ryerson; Tamiko R Katsumoto; Anthony K Shum; Paul J Wolters; Stefania Cerri; Luca Richeldi; Kirk D Jones; Talmadge E King; Harold R Collard
Journal:  Respir Med       Date:  2012-11-24       Impact factor: 3.415

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.