Literature DB >> 6477078

Trace element burdening of human tissues due to the corrosion of hip-joint prostheses made of cobalt-chromium alloys.

R Michel, J Hofmann, F Löer, J Zilkens.   

Abstract

Using instrumental neutron activation analysis, the concentrations of 18 elements were studied in human articular capsule and fascia lata before and after application of total endoprostheses of the hip joint made of cobalt-chromium alloys. Tissues from the vicinity of the implant showed extreme burdening by corrosion products (Co, Cr, Ni), as well as by Zr, Hf, and Ba from the bone cements. Tissues more distant from the implants exhibited lower, but still significant burdening. Moreover, some essential trace elements not contained in the implant materials were changed in the tissues after implantation. In order to clarify the dissolution of alloy constituents in biological media, the passivation of cobalt-chromium alloy was investigated by tracer techniques using Ringer's solution as a simple model of the body fluids. The passivation process lasted for more than 1 month and was accompanied by a selective dissolution of the alloys constituents in the order Ni greater than Co approximately Fe greater than Mo greater than Cr. A comparison of the tissue analyses with the corrosion experiments demonstrates that the distribution patterns of the corrosion products in the tissues are influenced by both the corrosion process and the biochemical properties of the corrosion products.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6477078     DOI: 10.1007/bf00389578

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  31 in total

1.  The ionization of metal implants in living tissues.

Authors:  A B FERGUSON; P G LAING; E S HODGE
Journal:  J Bone Joint Surg Am       Date:  1960-01       Impact factor: 5.284

2.  Metals in living tissues.

Authors:  A B FERGUSON
Journal:  Surg Clin North Am       Date:  1960-04       Impact factor: 2.741

3.  Malignant tumour at site of bone plating.

Authors:  A MCDOUGALL
Journal:  J Bone Joint Surg Br       Date:  1956-08

4.  Toxicity of metal particles in tissue culture. II. A new assay method using cell counts in the lag phase.

Authors:  M Mital; J Cohen
Journal:  J Bone Joint Surg Am       Date:  1968-04       Impact factor: 5.284

5.  Concentration of wear products in hair, blood, and urine after total hip replacement.

Authors:  R F Coleman; J Herrington; J T Scales
Journal:  Br Med J       Date:  1973-03-03

6.  An allergic reaction after internal fixation of a fracture using a vitallium plate.

Authors:  P P Symeonides; C Paschaloglou; S Papageorgiou
Journal:  J Allergy Clin Immunol       Date:  1973-04       Impact factor: 10.793

7.  Toxicity of metal particles in tissue culture. I. A new assay method using cell counts in the phase of replication.

Authors:  A M Pappas; J Cohen
Journal:  J Bone Joint Surg Am       Date:  1968-04       Impact factor: 5.284

8.  [Tissue burden with exogenous trace elements caused by roentgen contrast media in bone cements].

Authors:  F Löer; J Zilkens; R Michel; G Freisem-Broda; K H Bigalke
Journal:  Z Orthop Ihre Grenzgeb       Date:  1983 May-Jun

9.  [Biocompatibility of implants in orthopedics].

Authors:  J Harms; E Mäusle
Journal:  Hefte Unfallheilkd       Date:  1980

Review 10.  Ewing's sarcoma at the site of a metal plate.

Authors:  K J Tayton
Journal:  Cancer       Date:  1980-01-15       Impact factor: 6.860

View more
  3 in total

1.  [Chemical and biochemical characterization and level of metals in the periprosthetic fluid].

Authors:  P Mangione; D Chauveaux; C Baquey; J L Honton
Journal:  Int Orthop       Date:  1990       Impact factor: 3.075

Review 2.  Systemic effects of implanted prostheses made of cobalt-chromium alloys.

Authors:  R Michel; M Nolte; M Reich; F Löer
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

3.  Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation.

Authors:  N J Hallab; K Mikecz; C Vermes; A Skipor; J J Jacobs
Journal:  Mol Cell Biochem       Date:  2001-06       Impact factor: 3.396

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.