Literature DB >> 6475774

Long-term reproducibility of responses to programmed cardiac stimulation in spontaneous ventricular tachyarrhythmias.

M H Schoenfeld, B McGovern, H Garan, J N Ruskin.   

Abstract

Programmed electrical stimulation (PES) of the heart has been used to initiate and terminate ventricular tachyarrhythmias under controlled conditions in patients in whom these arrhythmias have occurred spontaneously. The long-term reproducibility of the response to programmed cardiac stimulation in patients with ventricular arrhythmias is unknown. Seventeen patients with previously documented spontaneously occurring ventricular tachyarrhythmias were evaluated: 5 with nonsustained ventricular tachycardia (VT), 10 with sustained VT and 2 with ventricular fibrillation. The underlying cardiac diagnosis was atherosclerotic coronary heart disease (CAD) in 11 patients, dilated cardiomyopathy in 2 patients, congenital heart disease in 1 patient and no structural heart disease in 3. All patients underwent PES in the absence of antiarrhythmic drug treatment, and patients with inducible VT underwent serial electrophysiologic-pharmacologic testing in an attempt to suppress the arrhythmia. All 17 patients were reexamined with PES at a mean of 18 months (range 2 to 42) after their initial electrophysiologic study, during which time none had a myocardial infarction or intervening cardiac surgery. Repeat electrophysiologic studies, performed in the absence of antiarrhythmic agents, were undertaken because of drug intolerance, availability of new drugs, recurrent arrhythmia or preoperative reevaluation. All 11 patients with CAD had inducible VT on both the first and second electrophysiologic evaluation. Of the 6 patients with no CAD, only 1 had inducible VT on both occasions. Thus, long-term reproducibility of PES-induced VT in patients with stable CAD appears to be high.

Entities:  

Mesh:

Year:  1984        PMID: 6475774     DOI: 10.1016/0002-9149(84)90249-2

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  An optimized method for the estimation of the respiratory rate from electrocardiographic signals: implications for estimating minute ventilation.

Authors:  Eric H Weiss; Omid Sayadi; Priya Ramaswamy; Faisal M Merchant; Naveen Sajja; Lori Foley; Shawna Laferriere; Antonis A Armoundas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2014-05-23       Impact factor: 4.733

2.  Factors likely to affect the long-term results of ventricular stimulation after myocardial infarction.

Authors:  Beatrice Brembilla-Perrot; Pierre Yves Zinzius; Laurent Groben; Luc Freysz; Lucian Muresan; Jerome Schwartz; Raphael P Martins; Soumaya Jarmouni; Ibrahim Nossier; Nicolas Sadoul; Hugues Blangy; Arnaud Terrier De La Chaise; Pierre Louis; Olivier Selton; Daniel Beurrier; Jean Marc Sellal
Journal:  Indian Pacing Electrophysiol J       Date:  2010-04-01

3.  Real-Time Closed-Loop Suppression of Repolarization Alternans Reduces Arrhythmia Susceptibility In Vivo.

Authors:  Faisal M Merchant; Omid Sayadi; Kwanghyun Sohn; Eric H Weiss; Dheeraj Puppala; Rajiv Doddamani; Jagmeet P Singh; E Kevin Heist; Chris Owen; Kanchan Kulkarni; Antonis A Armoundas
Journal:  Circ Arrhythm Electrophysiol       Date:  2020-05-20

4.  A novel lead configuration for optimal spatio-temporal detection of intracardiac repolarization alternans.

Authors:  Eric H Weiss; Faisal M Merchant; Andre d'Avila; Lori Foley; Vivek Y Reddy; Jagmeet P Singh; Theofanie Mela; Jeremy N Ruskin; Antonis A Armoundas
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-03-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.