Literature DB >> 6451234

Valve prosthesis--patient mismatch. A long-term sequela.

S H Rahimtoola, E Murphy.   

Abstract

A patient underwent mitral valve replacement in 1966 for severe mitral valve disease. The initial clinical result was excellent but symptoms recurred nine years later, and since 1969 he has had progressive cardiac enlargement. At present he is in functional class II and has massive cardiomegaly with gross enlargement of the left atrium, right ventricle, and right atrium. Cardiac catherisation showed "normal" prosthetic valve function, but on moderate exercise he developed severe left atrial and pulmonary arterial hypertension. His clinical course illustrates a long-term sequela of "valve prosthesis--patient mismatch".

Entities:  

Mesh:

Year:  1981        PMID: 6451234      PMCID: PMC482531          DOI: 10.1136/hrt.45.3.331

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  4 in total

1.  Left ventricular performance after acute myocardial infarction. Sectrum of functional abnormalities and importance of wall motion disturbances during convalescent phase.

Authors:  A Ehsani; S H Rahimtoola; M Z Sinno; H S Loeb; K M Rosen; R M Gunnar
Journal:  Arch Intern Med       Date:  1975-12

2.  An appreciation of mitral stenosis: II. Investigations and results.

Authors:  P WOOD
Journal:  Br Med J       Date:  1954-05-15

Review 3.  Natural history of mitral stenosis: a review.

Authors:  A Selzer; K E Cohn
Journal:  Circulation       Date:  1972-04       Impact factor: 29.690

Review 4.  The problem of valve prosthesis-patient mismatch.

Authors:  S H Rahimtoola
Journal:  Circulation       Date:  1978-07       Impact factor: 29.690

  4 in total
  10 in total

Review 1.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

2.  Aortic valve annular dimension in Indian population.

Authors:  Hannah Sugirthabai Rajila Rajendran; Sudha Seshayyan; Ashok Victor; Gangadevi Rajapandian
Journal:  J Clin Diagn Res       Date:  2013-09-10

3.  Factors affecting survival after mitral valve replacement in patients with prosthesis-patient mismatch.

Authors:  Abdulhameed Aziz; Jennifer S Lawton; Hersh S Maniar; Michael K Pasque; Ralph J Damiano; Marc R Moon
Journal:  Ann Thorac Surg       Date:  2010-10       Impact factor: 4.330

4.  Patient-prosthesis mismatch in the mitral position affects midterm survival and functional status.

Authors:  Denis Bouchard; Frédéric Vanden Eynden; Philippe Demers; Louis P Perrault; Michel Carrier; Raymond Cartier; Arsène J Basmadjian; Michel Pellerin
Journal:  Can J Cardiol       Date:  2010-12       Impact factor: 5.223

5.  Weight gain potential-a neglected entity during valve replacement.

Authors:  Vijayanand Palanisamy; Karthik Raman; Anjith Prakash Rajakumar; Anbarasu Mohanraj; Jacob Jamesraj; Ejaz Ahmed Sheriff; Valikapthalil Mathew Kurian; Rajan Sethuratnam
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-07-19

6.  Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch after Mitral Valve Replacement: A Chinese Multicenter Clinical Study.

Authors:  Hua Cao; Zhihuang Qiu; Liangwan Chen; Daozhong Chen; Qiang Chen
Journal:  Med Sci Monit       Date:  2015-08-27

7.  Huge Left Atrium Accompanied by Normally Functioning Prosthetic Valve.

Authors:  Feridoun Sabzi
Journal:  J Tehran Heart Cent       Date:  2015-01-08

8.  Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?

Authors:  Seung Hyun Lee; Byung Chul Chang; Young-Nam Youn; Hyun Chel Joo; Kyung-Jong Yoo; Sak Lee
Journal:  J Cardiothorac Surg       Date:  2017-10-10       Impact factor: 1.637

9.  Prosthesis-patient mismatch after mitral valve replacement: a single-centered retrospective analysis in East China.

Authors:  Armah M Akuffu; Haige Zhao; Junnan Zheng; Yiming Ni
Journal:  J Cardiothorac Surg       Date:  2018-10-03       Impact factor: 1.637

10.  Impact of prosthesis-patient mismatch on early and late outcomes after mitral valve replacement: a meta-analysis.

Authors:  Meng-Wei Tan; Yi-Fan Bai; Xiao-Hong Liu; Zhi-Yun Xu; Zhao An; Ye Ma; Li-Bo Zhao; Bai-Ling Li
Journal:  J Geriatr Cardiol       Date:  2020-08       Impact factor: 3.327

  10 in total