Literature DB >> 6448593

Matched elastic properties and successful arterial grafting.

R Walden, G J L'Italien, J Megerman, W M Abbott.   

Abstract

Clinical results from medium- and small-caliber arterial bypass grafts are unsatisfactory. Since elastic properties of grafts tested experimentally have been correlated with patency results, the compliance of the human femoral artery was compared with grafts currently in use: human saphenous vein (HSV), knitted Dacron (DAC), glutaraldehyde-treated umbilical cord vein (DBM), bovine heterograft, and expanded polytetrafluoroethylene (PTFE). This was correlated with clinical patency data for the different conduits in the femoropopliteal position. Increased patency correlated with a decreasing disparity between host artery and graft compliance. After two years, patency rates of the more compliant materials (HSV, DBM) exceeded 80%, while less than 45% of the incompliant grafts (DAC, PTFE) remained patent. Thus, clinical performance with synthetic grafts might be improved by use of prostheses in which the viscoelastic characteristics match those of arteries more closely.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6448593     DOI: 10.1001/archsurg.1980.01380100018004

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  18 in total

1.  Effect of compliance mismatch on flow disturbances in a model of an arterial graft replacement.

Authors:  F Miyawaki; T V How; D Annis
Journal:  Med Biol Eng Comput       Date:  1990-09       Impact factor: 2.602

2.  Biaxial biomechanical properties of self-assembly tissue-engineered blood vessels.

Authors:  Michael T Zaucha; Robert Gauvin; Francois A Auger; Lucie Germain; Rudolph L Gleason
Journal:  J R Soc Interface       Date:  2010-06-16       Impact factor: 4.118

3.  Fabricating mechanically improved silk-based vascular grafts by solution control of the gel-spinning process.

Authors:  Maria Rodriguez; Jonathan A Kluge; Daniel Smoot; Matthew A Kluge; Daniel F Schmidt; Christopher R Paetsch; Peter S Kim; David L Kaplan
Journal:  Biomaterials       Date:  2019-10-23       Impact factor: 12.479

4.  Mechanical and biocompatible characterizations of a readily available multilayer vascular graft.

Authors:  Krishna Madhavan; Winston H Elliott; Walter Bonani; Eric Monnet; Wei Tan
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-11-19       Impact factor: 3.368

5.  Cell layer-electrospun mesh composites for coronary artery bypass grafts.

Authors:  Josh D Erndt-Marino; Silvia Becerra-Bayona; Rebecca E McMahon; Aaron S Goldstein; Mariah S Hahn
Journal:  J Biomed Mater Res A       Date:  2016-05-04       Impact factor: 4.396

6.  The evolution of morphologic and biomechanical changes in reversed and in-situ vein grafts.

Authors:  R P Cambria; J Megerman; D C Brewster; D F Warnock; J Hasson; W M Abbott
Journal:  Ann Surg       Date:  1987-02       Impact factor: 12.969

7.  In vivo measurement of arterial pre-tension.

Authors:  S I Green; G S Schajer; D R Parker; A J Post; Y N Hsiang
Journal:  Med Biol Eng Comput       Date:  1995-11       Impact factor: 2.602

8.  Current PTFE grafts: a biomechanical, scanning electron, and light microscopic evaluation.

Authors:  K C Hanel; C McCabe; W M Abbott; J Fallon; J Megerman
Journal:  Ann Surg       Date:  1982-04       Impact factor: 12.969

9.  Dacron Velour prosthesis.

Authors:  D D Nghiem
Journal:  Ann Surg       Date:  1981-11       Impact factor: 12.969

10.  Flow dynamics across end-to-end vascular bypass graft anastomoses.

Authors:  Y H Kim; K B Chandran; T J Bower; J D Corson
Journal:  Ann Biomed Eng       Date:  1993 Jul-Aug       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.