Mechanical influences on the capnogram.

J Schena, J Thompson, R K Crone.   

Abstract

We found that altering aspirating flow rate (ASR) and sample tubing length (STL) affected the response time and capnogram of 2 different side-stream capnometers. Increased flow rate shortened rise time, transit time, and total delay time (TDT), whereas increased STL increased transit and TDTs but not rise time. Increasing rise time pushed the ascending limb of the capnogram to the right. Peak and baseline PCO2 values were accurate only when TDT did not exceed respiratory cycle time (RCT). Awareness of the potential for artifactual changes in the capnogram will avoid their misinterpretation as physiologic events.

Mesh:

Substances:

Year:  1984        PMID: 6430650     DOI: 10.1097/00003246-198408000-00015

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  9 in total

1.  Microstream capnograpy technology: a new approach to an old problem.

Authors:  Y Colman; B Krauss
Journal:  J Clin Monit Comput       Date:  1999-08       Impact factor: 2.502

Review 2.  Capnometry and anaesthesia.

Authors:  K Bhavani-Shankar; H Moseley; A Y Kumar; Y Delph
Journal:  Can J Anaesth       Date:  1992-07       Impact factor: 5.063

3.  End-tidal carbon dioxide measurements in critically ill neonates: a comparison of side-stream and mainstream capnometers.

Authors:  B A McEvedy; M E McLeod; H Kirpalani; G A Volgyesi; J Lerman
Journal:  Can J Anaesth       Date:  1990-04       Impact factor: 5.063

4.  Is measurement of end-tidal CO2 through a nasal cannula reliable?

Authors:  K Fukuda; T Ichinohe; Y Kaneko
Journal:  Anesth Prog       Date:  1997

5.  Use of long catheters for multipatient anesthetic monitoring at high respiratory frequencies.

Authors:  J C Turner
Journal:  J Clin Monit       Date:  1991-07

Review 6.  Terminology and the current limitations of time capnography: a brief review.

Authors:  K Bhavani-Shankar; A Y Kumar; H S Moseley; R Ahyee-Hallsworth
Journal:  J Clin Monit       Date:  1995-05

7.  Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques.

Authors:  A L Balogh; F Petak; G H Fodor; J Tolnai; Z Csorba; B Babik
Journal:  Br J Anaesth       Date:  2016-07       Impact factor: 9.166

8.  The most proximal and accurate site for sampling end-tidal CO2 in infants.

Authors:  L Halpern; B Bissonnette
Journal:  Can J Anaesth       Date:  1994-10       Impact factor: 5.063

9.  Enhanced photoacoustic gas analyser response time and impact on accuracy at fast ventilation rates during multiple breath washout.

Authors:  Alex Horsley; Kenneth Macleod; Ruchi Gupta; Nick Goddard; Nicholas Bell
Journal:  PLoS One       Date:  2014-06-03       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.