Literature DB >> 6425359

Evaluation of the automicrobic system for detection of resistance of Staphylococcus aureus to methicillin.

B F Woolfrey, R T Lally, M N Ederer.   

Abstract

The AutoMicrobic system (AMS) (Vitek System, Inc., Hazelwood, Mo.) was tested for its ability to determine oxacillin and gentamicin susceptibility of 98 known oxacillin-susceptible and 103 known oxacillin-resistant Staphylococcus aureus isolates. AMS and reference oxacillin susceptibility results were in agreement for all 95 (100%) oxacillin-susceptible isolates. In contrast, only 23 (22.3%) of the 103 known oxacillin-resistant isolates were correctly reported. For the known oxacillin-resistant isolates, 65 received AMS reports at 3 to 4 h, with only 9% being correct, whereas 38 were reported at 5 to 6 h, with 47% being correct. The reliability of AMS gentamicin susceptibility results was evaluated by testing the 198 S. aureus isolates in parallel with MIC-2000 broth dilution tests. AMS gentamicin susceptibility results were found to be reliable and essentially identical to MIC-2000 results. The possibility of improving AMS oxacillin resistance detection by using gentamicin resistance as a linked screening marker for oxacillin resistance was evaluated with data from the parallel AMS and MIC-2000 gentamicin susceptibility tests and from data accrued on recent clinical laboratory isolates. By these two approaches, respective sensitivities of 97 and 99.8%, and specificity of 72%, were found for detection of oxacillin-resistant isolates by using gentamicin resistance as a marker.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6425359      PMCID: PMC271096          DOI: 10.1128/jcm.19.4.464-467.1984

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  27 in total

1.  The Automicrobic System for urines.

Authors:  D P Nicholson; J A Koepke
Journal:  J Clin Microbiol       Date:  1979-12       Impact factor: 5.948

2.  Clinical laboratory evaluation of automated microbial detection/identification system in analysis of clinical urine specimens.

Authors:  H D Isenberg; T L Gavan; A Sonnenwirth; W I Taylor; J A Washington
Journal:  J Clin Microbiol       Date:  1979-08       Impact factor: 5.948

3.  Cost analysis of the Auto Microbic system urine identification card.

Authors:  A C Hamoudi; S Lin
Journal:  J Clin Microbiol       Date:  1981-10       Impact factor: 5.948

4.  Evaluation of the AutoMicrobic system for identification of glucose-nonfermenting gram-negative rods.

Authors:  S M Smith; K R Cundy; G L Gilardi; W Wong
Journal:  J Clin Microbiol       Date:  1982-02       Impact factor: 5.948

5.  An outbreak of infections caused by strains of Staphylococcus aureus resistant to methicillin and aminoglycosides. II. Epidemiologic studies.

Authors:  K Crossley; B Landesman; D Zaske
Journal:  J Infect Dis       Date:  1979-03       Impact factor: 5.226

6.  Sensitivity, specificity, and reproducibility of the automicrobic system (with the Enterobacteriaceae-plus biochemical card) for identifying clinical isolates of Gram- negative bacilli.

Authors:  A L Barry; T L Gavan; R E Badal; M J Telenson
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

7.  Methicillin-resistant Staphylococcus aureus: introduction and spread within a hospital.

Authors:  J E Peacock; F J Marsik; R P Wenzel
Journal:  Ann Intern Med       Date:  1980-10       Impact factor: 25.391

8.  Multi-laboratory evaluation of an automated microbial detection/identification system.

Authors:  P B Smith; T L Gavan; H D Isenberg; A Sonnenwirth; W I Taylor; J A Washington; A Balows
Journal:  J Clin Microbiol       Date:  1978-12       Impact factor: 5.948

9.  Reliability of the MS-2 system in detecting methicillin-resistant Staphylococcus aureus.

Authors:  J M Boyce; R L White; M C Bonner; W R Lockwood
Journal:  J Clin Microbiol       Date:  1982-02       Impact factor: 5.948

10.  Epidemic neonatal gentamicin-methicillin--resistant Staphylococcus aureus infection associated with nonspecific topical use of gentamicin.

Authors:  D R Graham; A Correa-Villasenor; R L Anderson; J H Vollman; W B Baine
Journal:  J Pediatr       Date:  1980-12       Impact factor: 4.406

View more
  3 in total

1.  Evaluation of the AutoMicrobic system Gram-Positive Susceptibility-MIC card for detection of oxacillin-resistant coagulase-negative staphylococci.

Authors:  B F Woolfrey; R T Lally; M N Ederer
Journal:  J Clin Microbiol       Date:  1986-03       Impact factor: 5.948

2.  Evaluation of the newly modified AutoMicrobic system gram-positive susceptibility-MIC card for detection of methicillin-resistant Staphylococcus aureus.

Authors:  R T Lally; M N Ederer; B F Woolfrey
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

3.  Misclassification of susceptible strains of Staphylococcus aureus as methicillin-resistant S. aureus By a rapid automated susceptibility testing system.

Authors:  J Ribeiro; F D Vieira; T King; J B D'Arezzo; J M Boyce
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.