Literature DB >> 6410164

A 4-MV CT scanner for radiation therapy; spectral properties of the therapy beam.

W Swindell.   

Abstract

A Clinac-4 therapy accelerator has been modified to function also as a computed tomography (CT) scanner. We report on measurements made to calibrate the beam. 104 Bismuth-germanate silicon-photodiode detectors were placed in a circular arc of radius 180 cm, centered on the source, in the arrangement of a third-generation CT scanner. With the beam collimated to a fan section and just filling the detectors, the signal S(chi), obtained with thickness chi of plastic phantom, closely followed the relationship S(chi)/S(0) = exp [- (alpha chi + beta chi 2)], where coefficients alpha and beta varied systematically over the extent of the beam. This result agrees with results of similar work by others. It may be explained in terms of the spectral changes that are known to be an inherent property of such beams. Expressions relating alpha and beta to the source spectral density are derived; also estimates of the source spectral density are calculated using the method of Laplace inversion. It is shown that scattered radiation arising from the fan beam within the scattering medium does not contribute significantly to the values of alpha and beta.

Entities:  

Mesh:

Year:  1983        PMID: 6410164     DOI: 10.1118/1.595280

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

Review 1.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

2.  A dual two dimensional electronic portal imaging device transit dosimetry model based on an empirical quadratic formalism.

Authors:  Y I Tan; M Metwaly; M Glegg; S P Baggarley; A Elliott
Journal:  Br J Radiol       Date:  2015-05-13       Impact factor: 3.039

3.  Radiosurgical Treatment Verification Using Removable Megavoltage Radiation Detectors.

Authors:  Cesare H Jenkins; Robert Kahn; Georg A Weidlich; John R Adler
Journal:  Cureus       Date:  2017-11-29

Review 4.  Improving radiation physics, tumor visualisation, and treatment quantification in radiotherapy with spectral or dual-energy CT.

Authors:  Matthijs Ferdinand Kruis
Journal:  J Appl Clin Med Phys       Date:  2021-11-07       Impact factor: 2.102

5.  Low-dose 2.5 MV cone-beam computed tomography with thick CsI flat-panel imager.

Authors:  Grace Tang; Christopher Moussot; Daniel Morf; Edward Seppi; Howard Amols
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  5 in total