Radiosurgical Treatment Verification Using Removable Megavoltage Radiation Detectors.

Cesare H Jenkins1, Robert Kahn1, Georg A Weidlich2, John R Adler3.   

Abstract

Introduction Accurate dose delivery is critical to the success of stereotactic radiosurgery. Unfortunately, verification of the accuracy of treatment delivery remains a challenging problem. Existing radiosurgery delivery paradigms are limited in their ability to verify the accurate delivery of radiation beams using data sampled from the beam after it has traversed the patient. The Zap-X Radiosurgery System (Zap Surgical Systems, San Carlos, CA) addresses this issue by implementing a fully integrated treatment delivery system that utilizes a factory commissioned megavoltage (MV) imager to measure the transmitted beam. The measured intensity is then compared with an expected value in order to confirm that treatment is proceeding as expected. The purpose of this study was to evaluate a prototype system and investigate the accuracy of an attenuation model used in generating the expected transmitted intensity values. Methods A prototype MV imager was used to measure transmitted beam intensities at various exposure levels and through several thicknesses of solid water. The data were used to evaluate imager linearity and model accuracy. Results Experimental results indicate that a quadratic attenuation model is appropriate for predicting beam attenuation and that the imager exhibits excellent dose linearity. Conclusions The MV imager system is shown to be capable of accurately acquiring the data needed to confirm treatment validity.

Entities:  

Keywords:  portal dosimetry; treatment verification

Year:  2017        PMID: 29392101      PMCID: PMC5788398          DOI: 10.7759/cureus.1889

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  9 in total

1.  AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.

Authors:  P R Almond; P J Biggs; B M Coursey; W F Hanson; M S Huq; R Nath; D W Rogers
Journal:  Med Phys       Date:  1999-09       Impact factor: 4.071

2.  Quantifying the performance of in vivo portal dosimetry in detecting four types of treatment parameter variations.

Authors:  C Bojechko; E C Ford
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

Review 3.  A literature review of electronic portal imaging for radiotherapy dosimetry.

Authors:  Wouter van Elmpt; Leah McDermott; Sebastiaan Nijsten; Markus Wendling; Philippe Lambin; Ben Mijnheer
Journal:  Radiother Oncol       Date:  2008-08-14       Impact factor: 6.280

4.  Report of AAPM TG 135: quality assurance for robotic radiosurgery.

Authors:  Sonja Dieterich; Carlo Cavedon; Cynthia F Chuang; Alan B Cohen; Jeffrey A Garrett; Charles L Lee; Jessica R Lowenstein; Maximian F d'Souza; David D Taylor; Xiaodong Wu; Cheng Yu
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

5.  A review of stereotactic radiosurgery practice in the management of skull base meningiomas.

Authors:  Elena Vera; J Bryan Iorgulescu; Daniel M S Raper; Karthik Madhavan; Brian E Lally; Jacques Morcos; Samy Elhammady; Jonathan Sherman; Ricardo J Komotar
Journal:  J Neurol Surg B Skull Base       Date:  2014-03-12

6.  A 4-MV CT scanner for radiation therapy; spectral properties of the therapy beam.

Authors:  W Swindell
Journal:  Med Phys       Date:  1983 May-Jun       Impact factor: 4.071

7.  Stereotactic radiosurgical treatment of brain metastases.

Authors:  J R Adler; R S Cox; I Kaplan; D P Martin
Journal:  J Neurosurg       Date:  1992-03       Impact factor: 5.115

8.  Quality and safety considerations in stereotactic radiosurgery and stereotactic body radiation therapy: Executive summary.

Authors:  Timothy D Solberg; James M Balter; Stanley H Benedict; Benedick A Fraass; Brian Kavanagh; Curtis Miyamoto; Todd Pawlicki; Louis Potters; Yoshiya Yamada
Journal:  Pract Radiat Oncol       Date:  2011-09-15

Review 9.  The role of stereotactic radiosurgery in the management of patients with newly diagnosed brain metastases: a systematic review and evidence-based clinical practice guideline.

Authors:  Mark E Linskey; David W Andrews; Anthony L Asher; Stuart H Burri; Douglas Kondziolka; Paula D Robinson; Mario Ammirati; Charles S Cobbs; Laurie E Gaspar; Jay S Loeffler; Michael McDermott; Minesh P Mehta; Tom Mikkelsen; Jeffrey J Olson; Nina A Paleologos; Roy A Patchell; Timothy C Ryken; Steven N Kalkanis
Journal:  J Neurooncol       Date:  2009-12-04       Impact factor: 4.130

  9 in total
  1 in total

1.  Characterization of a Novel 3 Megavolt Linear Accelerator for Dedicated Intracranial Stereotactic Radiosurgery.

Authors:  Georg A Weidlich; Mohan Bodduluri; Younes Achkire; Chris Lee; John R Adler
Journal:  Cureus       Date:  2019-03-19
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.