Literature DB >> 6390118

Derivation of gamma variate indicator dilution function from simple convective dispersion model of blood flow.

M D Harpen, M L Lecklitner.   

Abstract

The gamma variate function, commonly used to analyze time-activity curves obtained in nuclear medicine flow studies, is shown to be related to the solution to the differential equation obtained from a one-dimensional convective dispersive model of blood flow.

Mesh:

Substances:

Year:  1984        PMID: 6390118     DOI: 10.1118/1.595553

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Reconstruction of dynamic image series from undersampled MRI data using data-driven model consistency condition (MOCCO).

Authors:  Julia V Velikina; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2014-11-14       Impact factor: 4.668

2.  Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

Authors:  Andreas H Mahnken; Annabella Rauscher; Ernst Klotz; Georg Mühlenbruch; Marco Das; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

3.  Modeling systemic and renal gadolinium chelate transport with MRI.

Authors:  John R Votaw; Diego Martin
Journal:  Pediatr Radiol       Date:  2007-12-11

4.  Validating a local Arterial Input Function method for improved perfusion quantification in stroke.

Authors:  Lisa Willats; Soren Christensen; Henry K Ma; Geoffrey A Donnan; Alan Connelly; Fernando Calamante
Journal:  J Cereb Blood Flow Metab       Date:  2011-06-01       Impact factor: 6.200

5.  A new algorithm for deriving pulsatile blood flow waveforms tested using stimulated dynamic angiographic data.

Authors:  A M Seifalian; D J Hawkes; A C Colchester; K E Hobbs
Journal:  Neuroradiology       Date:  1989       Impact factor: 2.804

6.  Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

Authors:  Nivedita K Naresh; Xiao Chen; Eric Moran; Yikui Tian; Brent A French; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2015-07-20       Impact factor: 4.668

7.  The use of perfusion CT for the evaluation of therapy combining AZD2171 with gefitinib in cancer patients.

Authors:  Martijn R Meijerink; Hester van Cruijsen; Klaas Hoekman; Matthijs Kater; Cors van Schaik; Jan Hein T M van Waesberghe; Giuseppe Giaccone; Radu A Manoliu
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

8.  Body tumor CT perfusion protocols: optimization of acquisition scan parameters in a rat tumor model.

Authors:  Alessia Tognolini; Rachel Schor-Bardach; Oleg S Pianykh; Carol J Wilcox; Vassilios Raptopoulos; S Nahum Goldberg
Journal:  Radiology       Date:  2009-03-20       Impact factor: 11.105

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.