Literature DB >> 2779778

A new algorithm for deriving pulsatile blood flow waveforms tested using stimulated dynamic angiographic data.

A M Seifalian1, D J Hawkes, A C Colchester, K E Hobbs.   

Abstract

In vascular pathology the assessment of disease severity and monitoring of treatment requires quantitative and reproducible measurements of arterial blood flow. We have developed a new technique for processing sequences of dynamic digital X-ray angiographic images. We have tested it using computer simulated angiographic data which includes the effect of pulsatile blood flow and X-ray quantum noise. A parametric image was formed in which the image grey-level represents dye concentration as a function of time and distance along a vessel segment. Adjacent concentration--distance profiles in the parametric image were re-registered along the vessel axis until a match occurred. A match was defined as the point where the sum of squares of the differences in the two profiles was a minimum. The distance translated per frame interval is equal to the bolus velocity. We have tested several contrast medium injection methods including constant flow and a range of discrete pulses per second. The technique proved to be robust and independent of injection technique. Average blood flow was measured for simulated pulsatile waveforms with mean flows of up to 650 ml/min (peak velocities up to 186 cm/s) in a range of diameters from 2 mm to 6 mm. The standard deviation of the error in the mean flow estimates over the whole range of velocities and vessel sizes was +/- 1.4 cm/s.

Mesh:

Substances:

Year:  1989        PMID: 2779778     DOI: 10.1007/BF00344356

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  30 in total

1.  A METHOD FOR DETERMINATION OF BLOOD FLOW WITH USE OF ROENTGEN CONTRAST MEDIUM.

Authors:  B NORDENSTROEM; S GRIM
Journal:  Radiology       Date:  1965-04       Impact factor: 11.105

2.  Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known.

Authors:  J R WOMERSLEY
Journal:  J Physiol       Date:  1955-03-28       Impact factor: 5.182

3.  New videodensitometric method for measuring renal artery blood flow at routine arteriography: validation in the canine model.

Authors:  D P Link; B M Lantz; J M Foerster; J W Holcroft; M H Reid
Journal:  Invest Radiol       Date:  1979 Nov-Dec       Impact factor: 6.016

4.  Arterial blood-flow waveform measurement in intact animals: new digital radiographic technique.

Authors:  D K Swanson; P D Myerowitz; J O Hegge; K M Watson
Journal:  Radiology       Date:  1986-11       Impact factor: 11.105

5.  Studies on arterial flow patients - instantaneous velocity spectrums and their phasic changes - with directional ultrasonic Doppler technique.

Authors:  Y Nimura; H Matsuo; T Hayashi; A Kitabatake; S Mochizuki
Journal:  Br Heart J       Date:  1974-09

6.  Computer computations of cardiac output using the gamma function.

Authors:  C F Starmer; D O Clark
Journal:  J Appl Physiol       Date:  1970-02       Impact factor: 3.531

7.  Evaluation of Roentgen cinedensitometry for flow measurement in models and in the intact circulation.

Authors:  W Rutishauser; H Simon; J P Stucky; N Schad; G Noseda; J Wellauer
Journal:  Circulation       Date:  1967-12       Impact factor: 29.690

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  Effect of blood vessels on electromagnetic flowmeter sensitivity.

Authors:  V T O'Sullivan
Journal:  Phys Med Biol       Date:  1982-02       Impact factor: 3.609

10.  Review on the research and some aspects upon the modern development of densitometry, particularly roentgen-video-computer techniques.

Authors:  P H Heintzen
Journal:  Ann Radiol (Paris)       Date:  1978 May-Jun
View more
  2 in total

1.  Quantification of Blood Velocity with 4D Digital Subtraction Angiography Using the Shifted Least-Squares Method.

Authors:  Y Wu; G Shaughnessy; C A Hoffman; E L Oberstar; S Schafer; T Schubert; K L Ruedinger; B J Davis; C A Mistretta; C M Strother; M A Speidel
Journal:  AJNR Am J Neuroradiol       Date:  2018-09-13       Impact factor: 3.825

2.  Estimation of 2-D blood flow velocity map from cine-angiograms: algorithm using overlapping block set and illustration of vortex flow in abdominal aneurysm.

Authors:  N Sugimoto; C Uyama; T Sugahara; Y Yanagihara
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.