Literature DB >> 3916438

Cardiac applications of digital subtraction angiography.

R A Vogel, G B Mancini, E R Bates.   

Abstract

Recent developments in digital computer technology have enabled direct digital acquisition of radiographic images at spatial and temporal resolutions similar to that of cineradiography. Initially intended as a means of performing peripheral angiography, digital subtraction angiography has been increasingly applied to cardiac catheterization procedures. Advantages of cardiac digital subtraction angiography include the capabilities to: immediately replay, magnify and enhance angiographic studies during coronary artery interventions, perform left ventriculography with peripheral contrast injections and direct left ventriculography with substantially reduced contrast doses, perform bypass graft visualization using aortic root contrast injection, assess relative regional coronary blood flow and facilitate the quantification of ventriculographic and coronary stenosis parameters. Clinical comparisons of standard cineradiographic and digital angiographic studies have demonstrated very similar results.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3916438     DOI: 10.1007/bf01568671

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  51 in total

1.  The application of matched filtering to x-ray exposure reduction in digital subtraction angiography: clinical results.

Authors:  S J Riederer; D R Enzmann; A L Hall; N J Pelc; W T Djang
Journal:  Radiology       Date:  1983-02       Impact factor: 11.105

2.  Measurement of left ventricular ejection fraction by videodensitometric analysis of digital subtraction angiograms.

Authors:  J Tobis; O Nalcioglu; A Seibert; W D Johnston; W L Henry
Journal:  Am J Cardiol       Date:  1983-10-01       Impact factor: 2.778

3.  Detection and assessment of severity of regional ischemic left ventricular dysfunction by digital fluoroscopy.

Authors:  K H Gerber; R A Slutsky; V Bhargava; W L Ashburn; C B Higgins
Journal:  Am Heart J       Date:  1982-07       Impact factor: 4.749

4.  Left ventricular imaging with digital subtraction angiography using intravenous contrast injection and fluoroscopic exposure levels.

Authors:  J Tobis; O Nacioglu; W D Johnston; A Seibert; L T Iseri; W Roeck; U Elkayam; W L Henry
Journal:  Am Heart J       Date:  1982-07       Impact factor: 4.749

5.  A technique of scatter and glare correction for videodensitometric studies in digital subtraction videoangiography.

Authors:  C G Shaw; D L Ergun; P D Myerowitz; M S Van Lysel; C A Mistretta; W C Zarnstorff; A B Crummy
Journal:  Radiology       Date:  1982-01       Impact factor: 11.105

6.  The current status of reactions to intravenous contrast media.

Authors:  G Ansell; M C Tweedie; C R West; P Evans; L Couch
Journal:  Invest Radiol       Date:  1980 Nov-Dec       Impact factor: 6.016

7.  Comparison of stress digital ventriculography, stress thallium scintigraphy, and digital fluoroscopy in the diagnosis of coronary artery disease in subjects without prior myocardial infarction.

Authors:  R Detrano; C Simpfendorfer; K Day; E E Salcedo; G Rincon; J R Kramer; R E Hobbs; E K Shirey; M Rollins; W C Sheldon
Journal:  Am J Cardiol       Date:  1985-09-01       Impact factor: 2.778

8.  Digital intravenous ventriculography. Comparison of volumes from mask-mode and nonsubtracted images with thermodilution and sonocardiometric measurements.

Authors:  R A Slutsky; G B Mancini; S Norris; W L Ashburn; C B Higgins
Journal:  Invest Radiol       Date:  1983 Jul-Aug       Impact factor: 6.016

9.  Intravenous vs. left ventricular injection of ionic contrast material: hemodynamic implications for digital subtraction angiography.

Authors:  G B Mancini; D R Ostrander; R A Slutsky; R Shabetai; C B Higgins
Journal:  AJR Am J Roentgenol       Date:  1983-03       Impact factor: 3.959

10.  Digital angiography in assessment of ventricular function and wall motion during pacing in patients with coronary artery disease.

Authors:  J Tobis; O Nalcioglu; W D Johnston; A Seibert; L T Iseri; W Roeck; W L Henry
Journal:  Am J Cardiol       Date:  1983-03-01       Impact factor: 2.778

View more