Literature DB >> 6352557

AUR Memorial Award. Determinants of contrast enhancement for intravenous digital subtraction angiography.

F H Burbank.   

Abstract

Mask mode intravenous digital subtraction angiography (IV-DSA) image quality is directly dependent on the arterial time-concentration curve peak and width produced by contrast media. Curves with high peak iodine concentration produce excellent difference images. Curves that are narrow appear and disappear quickly and minimize movement artifacts. Using a noninvasive x-ray technique for quantitative measurement of contrast media time-concentration curve parameters and cardiac output, three experimental data bases were analyzed. From the analyses, equations defining curve peak and width were derived and validated. Width is proportional to central blood volume and inversely proportional to cardiac output. Peak is proportional to the quantity of contrast media injected and inversely proportional to central blood volume. Hypertonic contrast media increases central blood volume and lowers curve peak. Optimal contrast media for IV-DSA is low in concentration and high in volume. In addition, low concentration contrast media may be more comfortable for the patient causing fewer motion artifacts.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6352557     DOI: 10.1097/00004424-198307000-00004

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  A high-precision contrast injector for small animal x-ray digital subtraction angiography.

Authors:  Ming de Lin; Lutao Ning; Cristian T Badea; Nilesh N Mistry; Yi Qi; G Allan Johnson
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

2.  A new algorithm for deriving pulsatile blood flow waveforms tested using stimulated dynamic angiographic data.

Authors:  A M Seifalian; D J Hawkes; A C Colchester; K E Hobbs
Journal:  Neuroradiology       Date:  1989       Impact factor: 2.804

3.  Comparison of brachiocephalic angiography and IVDSA in the same group of patients.

Authors:  H O Thijssen; J L Merx; J E Mostart; M A Thijssen; R W Chung; H Schoonderwaldt; A Keyser
Journal:  Neuroradiology       Date:  1988       Impact factor: 2.804

Review 4.  Left ventricular imaging by digital subtraction angiography.

Authors:  R A Vogel
Journal:  Int J Card Imaging       Date:  1988

5.  Improvement of IVDSA of the brachiocephalic arteries using a non-ionic contrast medium.

Authors:  H O Thijssen; J L Merx; M A Thijssen; A Keyser; H Schoonderwaldt; R Wong Chung
Journal:  Neuroradiology       Date:  1988       Impact factor: 2.804

  5 in total