Literature DB >> 6344560

Computer tomography (CT) orientated rotary stereotactic system. A technical note.

A A Patil.   

Abstract

The system consists of an inverted U-shaped frame with right angled corners, so mounted that it can be adjusted vertically, antero-posteriorly and made to rotate on an axis ("the axis of the frame") formed by its free ends. The frame carries an arc probe carrier whose probe holder slides on an arc which is centered on the axis of the frame. The centre of the probe holder and axis of fram lie in one plane "The plane of probe". After positioning the patient in the frame on the CT table, using either table indexing or laser positioning light, the plane of the probe is brought in the CT plane of the target. Once in this CT plane, direct measurements can be obtained so as to bring the axis of the frame passing through the target and centering the arc on the target. The frame can then be rotated to any desired angle and the probe holder can be moved to any position on the arc without altering the direction of the probe with respect to the target. As the structures in the probe plane are constructed of plastic, it can be used within the scanner with practically no artifacts, and direct measurements can be obtained without any calculations. This system can be used in any total body scanner with standard features and no special computer programming is necessary. This is a simple and truly CT-oriented stereotactic system with a high degree of accuracy.

Entities:  

Mesh:

Year:  1983        PMID: 6344560     DOI: 10.1007/bf01406198

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  12 in total

1.  Stereotaxic computed tomography.

Authors:  M Bergström; T Greitz
Journal:  AJR Am J Roentgenol       Date:  1976-07       Impact factor: 3.959

2.  Stereotactic localization (with computerized tomographic scanning), biopsy, and radiofrequency treatment of deep brain lesions.

Authors:  C A Gleason; B L Wise; B Feinstein
Journal:  Neurosurgery       Date:  1978 May-Jun       Impact factor: 4.654

3.  Stereotactic surgery with image processing of computerized tomographic scans.

Authors:  R D Penn; W W Whisler; C A Smith; W A Yasnoff
Journal:  Neurosurgery       Date:  1978 Sep-Oct       Impact factor: 4.654

4.  Computed tomography/guided stereotactic surgery: conception and development of a new stereotactic methodology.

Authors:  J H Perry; A E Rosenbaum; L D Lunsford; C A Swink; D S Zorub
Journal:  Neurosurgery       Date:  1980-10       Impact factor: 4.654

5.  Compute tomography-oriented stereotactic system.

Authors:  A A Patil
Journal:  Neurosurgery       Date:  1982-03       Impact factor: 4.654

6.  A computed tomographic stereotactic adaptation system.

Authors:  S Goerss; P J Kelly; B Kall; G J Alker
Journal:  Neurosurgery       Date:  1982-03       Impact factor: 4.654

7.  Computed tomography stereotactic head clamp.

Authors:  A A Patil
Journal:  Acta Neurochir (Wien)       Date:  1982       Impact factor: 2.216

8.  Stereotactic surgical system controlled by computed tomography.

Authors:  M Koslow; M G Abele; R C Griffith; G A Mair; N E Chase
Journal:  Neurosurgery       Date:  1981-01       Impact factor: 4.654

9.  Stereotaxic computerized tomography with a GE 8800 scanner.

Authors:  J Boëthius; M Bergström; T Greitz
Journal:  J Neurosurg       Date:  1980-06       Impact factor: 5.115

10.  Direct visualization of intracranial tumours in stereotactic and angiographic films by computer calculation of longitudinal CT-sections: a new method for stereotactic localization of tumour outlines.

Authors:  W Schlegel; H Scharfenberg; V Sturm; H Penzholz; W J Lorenz
Journal:  Acta Neurochir (Wien)       Date:  1981       Impact factor: 2.216

View more
  1 in total

1.  Stereotactic excision of deep brain lesions using probe guided brain retractor.

Authors:  A A Patil
Journal:  Acta Neurochir (Wien)       Date:  1987       Impact factor: 2.216

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.