Literature DB >> 6991649

Stereotaxic computerized tomography with a GE 8800 scanner.

J Boëthius, M Bergström, T Greitz.   

Abstract

A stereotaxic system is described that uses computerized tomography scanning for target localization. This system is unique in that the sterotaxic localization may be carried out using the scanner computer without the addition of any extra software. The hardware of the system is built up around a base plate which is fastened to the scanner's patient table. The head is positioned and fixed to the base plate with aluminum bars, which are fixed to the calvaria with screws. Various stereotaxic devices may be fastened to the base plate. The system has been in clinical use for 4 months at the time of writing. Its main application has been in tumor biopsies, but it has also been used for functional operations.

Entities:  

Mesh:

Year:  1980        PMID: 6991649     DOI: 10.3171/jns.1980.52.6.0794

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  14 in total

1.  Computer-assisted planning of stereotactic neurosurgical procedures.

Authors:  C Giorgi; S D Casolino; A Franzini; D Servello; A Passerini; G Broggi; F Pluchino
Journal:  Childs Nerv Syst       Date:  1989-10       Impact factor: 1.475

2.  A method of stereotaxic localization adopted for conventional and digital radiography.

Authors:  M Bergström; T Greitz; T Ribbe
Journal:  Neuroradiology       Date:  1986       Impact factor: 2.804

3.  Magnetic Resonance Imaging (MRI) stereotaxis using the Patil System. A technical note.

Authors:  A A Patil; W S Yamanashi; J W Ross-Duggan; P D Lester
Journal:  Acta Neurochir (Wien)       Date:  1986       Impact factor: 2.216

4.  An adaptor to the Leksell stereotaxic instrument for digital coordinate determination in radiography.

Authors:  M Bergström; T Greitz; T Ribbe
Journal:  Neuroradiology       Date:  1987       Impact factor: 2.804

5.  CT-guided and computer assisted stereotactic biopsy. Technique, results, indications.

Authors:  J Voges; R Schröder; H Treuer; O Pastyr; W Schlegel; W J Lorenz; V Sturm
Journal:  Acta Neurochir (Wien)       Date:  1993       Impact factor: 2.216

6.  Results of 200 intracranial stereotactic biopsies.

Authors:  P Grunert; K Ungersböck; J Bohl; K Kitz; N Hopf
Journal:  Neurosurg Rev       Date:  1994       Impact factor: 3.042

7.  CT-guided stereotactic biopsies using a modified frame and Gildenberg techniques.

Authors:  D E Bullard; B S Nashold; D Osborne; P C Burger; P Dubois
Journal:  J Neurol Neurosurg Psychiatry       Date:  1984-06       Impact factor: 10.154

8.  Computer tomography (CT) orientated rotary stereotactic system. A technical note.

Authors:  A A Patil
Journal:  Acta Neurochir (Wien)       Date:  1983       Impact factor: 2.216

9.  Stereotactic computer tomography with a modified Riechert-Mundinger device as the basis for integrated stereotactic neuroradiological investigations.

Authors:  V Sturm; O Pastyr; W Schlegel; H Scharfenberg; H J Zabel; G Netzeband; S Schabbert; W Berberich
Journal:  Acta Neurochir (Wien)       Date:  1983       Impact factor: 2.216

10.  Probe holder for stereotactic surgery in the CT scanner. A technical note.

Authors:  L D Lunsford; L Leksell; B Jernberg
Journal:  Acta Neurochir (Wien)       Date:  1983       Impact factor: 2.216

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.