Literature DB >> 7010201

Stereotactic surgical system controlled by computed tomography.

M Koslow, M G Abele, R C Griffith, G A Mair, N E Chase.   

Abstract

The three-dimensional data obtained by computed tomographic (CT) scanning offer an advantage in using this imaging technique for stereotactic surgical procedures. This requires interfacing of CT image data with a stereotactic guide. In the performance of functional procedures where the surgical target must be identified from brain landmarks, such as the anterior and posterior commissures, an image reconstruction technique that presents in an image high spatial resolution structural information must be used. The description of a fully hardware- and software-interfaced CT-directed stereotactic surgical system is presented. The logic of operation and examples of images reconstructed with a high spatial resolution algorithm are illustrated. The experimentally determined measurement of an electrode tip localization with this system is within 1 pixel or +/- 0.5 mm in any direction.

Mesh:

Year:  1981        PMID: 7010201     DOI: 10.1227/00006123-198101000-00014

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  10 in total

1.  CT guided functional stereotaxic surgery.

Authors:  J D McKean; P B Allen; L J Filipow; J D Miller
Journal:  Acta Neurochir (Wien)       Date:  1987       Impact factor: 2.216

2.  Magnetic Resonance Imaging (MRI) stereotaxis using the Patil System. A technical note.

Authors:  A A Patil; W S Yamanashi; J W Ross-Duggan; P D Lester
Journal:  Acta Neurochir (Wien)       Date:  1986       Impact factor: 2.216

3.  Improvement of cerebral blood flow following stereotactic surgery in patients with putaminal haemorrhage.

Authors:  Y Tanizaki
Journal:  Acta Neurochir (Wien)       Date:  1988       Impact factor: 2.216

4.  Radiological aspects of CT-guided stereotactic neurosurgical procedures.

Authors:  R E Anderson; D G Thomas; G H du Boulay
Journal:  Neuroradiology       Date:  1983       Impact factor: 2.804

5.  CT-guided stereotactic neurosurgery: experience in 24 cases with a new stereotactic system.

Authors:  D G Thomas; R E Anderson; G H du Boulay
Journal:  J Neurol Neurosurg Psychiatry       Date:  1984-01       Impact factor: 10.154

6.  Computer tomography (CT) orientated rotary stereotactic system. A technical note.

Authors:  A A Patil
Journal:  Acta Neurochir (Wien)       Date:  1983       Impact factor: 2.216

7.  Probe holder for stereotactic surgery in the CT scanner. A technical note.

Authors:  L D Lunsford; L Leksell; B Jernberg
Journal:  Acta Neurochir (Wien)       Date:  1983       Impact factor: 2.216

8.  CT control of stereotactic surgery in the diencephalon.

Authors:  P Dettori; F Colombo; V Pinna; A Benedetti
Journal:  Neuroradiology       Date:  1982       Impact factor: 2.804

9.  Transverse axial plane anatomy of the temporal bone employing high spatial resolution computed tomography.

Authors:  E J Russell; M Koslow; P Lasjaunias; R T Bergeron; N Chase
Journal:  Neuroradiology       Date:  1982       Impact factor: 2.804

10.  Computed tomography stereotactic head clamp.

Authors:  A A Patil
Journal:  Acta Neurochir (Wien)       Date:  1982       Impact factor: 2.216

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.