Literature DB >> 6333690

Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation.

C E Floyd, R J Jaszczak, C C Harris, R E Coleman.   

Abstract

Energy and spatial projection distributions were simulated for gamma camera imaging of multiple order Compton scattered photons. SPECT imaging of a line source of radioactivity located in a water filled cylindrical phantom was modelled using Monte Carlo techniques. Photon trajectories were followed from emission to detection including the effects of all physical interactions and the resulting energy spectra and spatial projections were sorted as a function of the number of times the photon underwent Compton scattering before detection. Analysis of energy spectra demonstrates that Compton events up to second order overlap with the non-scattered events and distributions are peaked at lower energies as the scattering order increases. Analysis of spatial projections shows that, with increasing order, Compton events produce tails on the line spread function which progress from roughly exponential to nearly flat distributions. The use of Monte Carlo modelling thus allows a detailed investigation of the spatial and energy distribution of Compton scatter which could not be performed using present experimental techniques.

Entities:  

Mesh:

Year:  1984        PMID: 6333690     DOI: 10.1088/0031-9155/29/10/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging.

Authors:  Y K Dewaraja; M Ljungberg; K F Koral
Journal:  J Nucl Med       Date:  2000-01       Impact factor: 10.057

2.  Correction of scattered photons in Tc-99m imaging by means of a photopeak dual-energy window acquisition.

Authors:  A Kojima; A Tsuji; Y Takaki; S Tomiguchi; M Hara; M Matsumoto; M Takahashi
Journal:  Ann Nucl Med       Date:  1992-08       Impact factor: 2.668

Review 3.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

4.  Experimental analysis of scattered photons in Tc-99m imaging with a gamma camera.

Authors:  A Kojima; M Matsumoto; M Takahashi
Journal:  Ann Nucl Med       Date:  1991-11       Impact factor: 2.668

5.  A multi-center phantom study comparing image resolution from three state-of-the-art SPECT-CT systems.

Authors:  Tyler Hughes; Sergey Shcherbinin; Anna Celler
Journal:  J Nucl Cardiol       Date:  2009-08-06       Impact factor: 5.952

6.  Analysis of the reconstructibility and noise properties of scattered photons in 99mTc SPECT.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1997-12       Impact factor: 3.609

7.  Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction.

Authors:  D J Kadrmas; E C Frey; S S Karimi; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

8.  Evaluation of SPET quantification of simultaneous emission and transmission imaging of the brain using a multidetector SPET system with the TEW scatter compensation method and fan-beam collimation.

Authors:  T Ichihara; N Motomura; K Ogawa; H Hasegawa; J Hashimoto; A Kubo
Journal:  Eur J Nucl Med       Date:  1996-10

Review 9.  Absolute quantification in SPECT.

Authors:  Philipp Ritt; Hans Vija; Joachim Hornegger; Torsten Kuwert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

Review 10.  Cardiac nuclear medicine tomographic systems.

Authors:  K Jordan; B O Knoop
Journal:  Eur J Nucl Med       Date:  1988
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.