Literature DB >> 8781132

Evaluation of SPET quantification of simultaneous emission and transmission imaging of the brain using a multidetector SPET system with the TEW scatter compensation method and fan-beam collimation.

T Ichihara1, N Motomura, K Ogawa, H Hasegawa, J Hashimoto, A Kubo.   

Abstract

A gamma camera system which is able to acquire simultaneous single-photon emission tomographic (SPET) data and gamma ray transmission computed tomography (TCT) data for brain study using external rod sources and fan-beam collimators was developed and evaluated. Since the three external rod sources were located at the focal points of fan-beam collimators, which also happened to be the apexes of the equilateral triangle defined by the three detectors, simultaneous SPET and TCT scan could be performed using a 120 degrees shared scan. Therefore, the proposed system required less than one-third of the scanning time of a single-head system. Since the combination of rod sources and fan-beam collimators decreased the scatter component in transmission data without a slit collimator for each rod source, the radioactivity of the rod source was less than one-tenth of the previous investigations. For evaluation, we used two isotopes, thallium-201 for TCT and technetium-99m for SPET. The cross-contamination of transmission and emission was well compensated using the triple energy window (TEW) method. In a separate TCT scan, the measured attenuation coefficient of 201Tl for water was 0.19+/-0.01 cm-1, while in a simultaneous scan, it was 0. 20+/-0.01 cm-1. The measured attenuation coefficient for water agreed well with the narrow-beam (theoretical) value of 0.187 cm-1. In SPET images, scatter compensation was also performed using the TEW method and attenuation compensation was done using the measured attenuation map. The results showed the feasibility of simultaneous SPET and TCT scanning using the TEW method to obtain quantitative SPET images.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8781132     DOI: 10.1007/bf01367583

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  13 in total

1.  A practical method for position-dependent Compton-scatter correction in single photon emission CT.

Authors:  K Ogawa; Y Harata; T Ichihara; A Kubo; S Hashimoto
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

2.  Whole-body single-photon emission computed tomography using dual, large-field-of-view scintillation cameras.

Authors:  R J Jaszczak; L T Chang; N A Stein; F E Moore
Journal:  Phys Med Biol       Date:  1979-11       Impact factor: 3.609

3.  Improved SPECT using simultaneous emission and transmission tomography.

Authors:  D L Bailey; B F Hutton; P J Walker
Journal:  J Nucl Med       Date:  1987-05       Impact factor: 10.057

4.  [An attenuation correction method of single photon emission computed tomography using gamma ray transmission CT].

Authors:  K Ogawa; Y Takagi; A Kubo; S Hashimoto; T Sannmiya; Y Okano; T Morozumi; M Nakajima; S Yuta
Journal:  Kaku Igaku       Date:  1985-04

5.  A scanning line source for simultaneous emission and transmission measurements in SPECT.

Authors:  P Tan; D L Bailey; S R Meikle; S Eberl; R R Fulton; B F Hutton
Journal:  J Nucl Med       Date:  1993-10       Impact factor: 10.057

6.  Physical performance evaluation of the Toshiba GCA-9300A triple-headed system.

Authors:  K Kouris; G A Clarke; P H Jarritt; C E Townsend; S N Thomas
Journal:  J Nucl Med       Date:  1993-10       Impact factor: 10.057

7.  Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT.

Authors:  T Ichihara; K Ogawa; N Motomura; A Kubo; S Hashimoto
Journal:  J Nucl Med       Date:  1993-12       Impact factor: 10.057

8.  A transmission-dependent method for scatter correction in SPECT.

Authors:  S R Meikle; B F Hutton; D L Bailey
Journal:  J Nucl Med       Date:  1994-02       Impact factor: 10.057

9.  Transmission computed tomography imaging of the head with a SPECT system and a collimated line source.

Authors:  B J Kemp; F S Prato; R L Nicholson; L Reese
Journal:  J Nucl Med       Date:  1995-02       Impact factor: 10.057

10.  Quantitative SPECT reconstruction of iodine-123 data.

Authors:  D R Gilland; R J Jaszczak; K L Greer; R E Coleman
Journal:  J Nucl Med       Date:  1991-03       Impact factor: 10.057

View more
  2 in total

1.  Which attenuation coefficient to use in combined attenuation and scatter corrections for quantitative brain SPET?

Authors:  Habib Zaidi; Marie-Louise Montandon
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-07       Impact factor: 9.236

2.  Three-dimensional brain phantom containing bone and grey matter structures with a realistic head contour.

Authors:  Hidehiro Iida; Yuki Hori; Kenji Ishida; Etsuko Imabayashi; Hiroshi Matsuda; Masaaki Takahashi; Hirotaka Maruno; Akihide Yamamoto; Kazuhiro Koshino; Junichiro Enmi; Satoshi Iguchi; Tetsuaki Moriguchi; Hidekazu Kawashima; Tsutomu Zeniya
Journal:  Ann Nucl Med       Date:  2012-09-26       Impact factor: 2.668

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.