Literature DB >> 6323554

Spin lattice relaxation time measurements in two-dimensional nuclear magnetic resonance imaging: corrections for plane selection and pulse sequence.

B R Rosen, I L Pykett, T J Brady.   

Abstract

Accurate determination of relaxation times has become increasingly important in efforts to determine the diagnostic specificity of nuclear magnetic resonance (NMR) imaging. Techniques used in NMR imaging, not routinely employed in conventional NMR spectroscopy, can significantly affect the resulting relaxation time determinations. For the saturation recovery (SR) approach of T1 measurement used in our laboratory, these include selective excitation to define the image plane and magnetization refocusing for NMR signal acquisition. Computer modeling of the Bloch equations shows that errors well over 50% can be made in image derived T1 measurements if the conventional SR relation between signal intensity and the 90-90 degrees interpulse delay, tr, is used. However, corrected expressions can be derived for the actual pulse and gradient sequence used by our imaging system, and phantom data acquired in imaging experiments have verified the validity of these equations. This allows for the correction of T1 data to compensate for systematic bias introduced during imaging procedures and suggests a means whereby errors introduced by radio frequency inhomogeneities across the imaging volume can be reduced.

Entities:  

Mesh:

Year:  1984        PMID: 6323554

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  5 in total

1.  Rapid measurement of T1 with spatially selective pre-inversion pulses.

Authors:  E McVeigh; A Yang; E Zerhouni
Journal:  Med Phys       Date:  1990 Jan-Feb       Impact factor: 4.071

2.  Information in magnetic resonance images: evaluation of signal, noise and contrast.

Authors:  J P De Wilde; J A Lunt; K Straughan
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

3.  Phase and sensitivity of receiver coils in magnetic resonance imaging.

Authors:  E R McVeigh; M J Bronskill; R M Henkelman
Journal:  Med Phys       Date:  1986 Nov-Dec       Impact factor: 4.071

4.  Optimization of MR protocols: a statistical decision analysis approach.

Authors:  E R McVeigh; M J Bronskill; R M Henkelman
Journal:  Magn Reson Med       Date:  1988-03       Impact factor: 4.668

Review 5.  Basic principles of magnetic resonance imaging--an update.

Authors:  A L Scherzinger; W R Hendee
Journal:  West J Med       Date:  1985-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.