Rapid measurement of T1 with spatially selective pre-inversion pulses.

E McVeigh1, A Yang, E Zerhouni.   

Abstract

A method is described for rapidly obtaining a multipoint estimate of T1 from a sample that is homogeneous over a few millimeters. An image of the longitudinal recovery curve is produced through the application of successive "pre-inversion" slices that are perpendicular to the imaging slice. These pre-inversion pulses are analogous to pre-saturation pulses, but they are much thinner and the tip angle is 180 degrees. The baseline for the recovery is measured from sections of the sample that have not been perturbed by the slice selective pre-inversion pulses. The existence of the baseline value and the lack of slice profile effects allows a quick T1 estimate (QT1) to be made with a simple linear regression algorithm. The QT1 values are found to correlate very well with T1 values measured with the scanner in "spectrometer' mode, for volumes as small as 5 x 5 x 5 mm. Possible applications are T1 estimates in homogeneous samples and tissues, and scouting the T1 range of a tissue to be measured with higher resolution volume localization techniques.

Mesh:

Year:  1990        PMID: 2308543      PMCID: PMC2041915          DOI: 10.1118/1.596543

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Optimizing the precision in T1 relaxation estimation using limited flip angles.

Authors:  H Z Wang; S J Riederer; J N Lee
Journal:  Magn Reson Med       Date:  1987-11       Impact factor: 4.668

2.  Phase and sensitivity of receiver coils in magnetic resonance imaging.

Authors:  E R McVeigh; M J Bronskill; R M Henkelman
Journal:  Med Phys       Date:  1986 Nov-Dec       Impact factor: 4.071

3.  Rapid calculation of T1 using variable flip angle gradient refocused imaging.

Authors:  E K Fram; R J Herfkens; G A Johnson; G H Glover; J P Karis; A Shimakawa; T G Perkins; N J Pelc
Journal:  Magn Reson Imaging       Date:  1987       Impact factor: 2.546

4.  A comparison of one-shot and recovery methods in T1 imaging.

Authors:  A P Crawley; R M Henkelman
Journal:  Magn Reson Med       Date:  1988-05       Impact factor: 4.668

5.  Spin lattice relaxation time measurements in two-dimensional nuclear magnetic resonance imaging: corrections for plane selection and pulse sequence.

Authors:  B R Rosen; I L Pykett; T J Brady
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

6.  Strategies and tactics in NMR imaging relaxation time measurements. I. Minimizing relaxation time errors due to image noise--the ideal case.

Authors:  R J Kurland
Journal:  Magn Reson Med       Date:  1985-04       Impact factor: 4.668

  6 in total
  1 in total

1.  Optimization of tag thickness for measuring position with magnetic resonance imaging.

Authors:  E Atalar; E R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.