Literature DB >> 6284793

Comparison of an enzyme immunoassay with electron microscopic procedures for detecting rotavirus.

A S Rubenstein, M F Miller.   

Abstract

The sensitivity and specificity of an enzyme immunoassay (Rotazyme), an ongrid immunoelectron microscopy procedure, and conventional negative stain electron microscopic techniques were compared. By using partially purified human rotavirus and simian rotavirus (SA-11) of known particle concentration, the enzyme immunoassay was essentially equivalent to the immunoelectron microscopic procedure and significantly more sensitive than conventional electron microscopic techniques. The level of sensitivity was approximately 10(6) particles per ml for simian rotavirus SA-11 and 10(7) particles per ml for human rotavirus. In an evaluation of 455 clinical samples by these techniques, a sensitivity of 98% and specificity of 92% were demonstrated. Samples negative by the immunoelectron microscopic procedure and positive by enzyme immunoassay could be confirmed by a blocking assay.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6284793      PMCID: PMC272217          DOI: 10.1128/jcm.15.5.938-944.1982

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  30 in total

1.  Quantitative studies of oncornaviruses in thin sections.

Authors:  M F Miller; P T Allen; L Dmochowski
Journal:  J Gen Virol       Date:  1973-10       Impact factor: 3.891

2.  Protein kinase in enveloped herpes simplex virions.

Authors:  A S Rubenstein; M Gravell; R Darlington
Journal:  Virology       Date:  1972-10       Impact factor: 3.616

3.  Relation between viruses from acute gastroenteritis of children and newborn calves.

Authors:  T H Flewett; A S Bryden; H Davies; G N Woode; J C Bridger; J M Derrick
Journal:  Lancet       Date:  1974-07-13       Impact factor: 79.321

4.  Virus particles in epithelial cells of duodenal mucosa from children with acute non-bacterial gastroenteritis.

Authors:  R F Bishop; G P Davidson; I H Holmes; B J Ruck
Journal:  Lancet       Date:  1973-12-08       Impact factor: 79.321

5.  Detection of a new virus by electron microscopy of faecal extracts from children with acute gastroenteritis.

Authors:  R F Bishop; G P Davidson; I H Holmes; B J Ruck
Journal:  Lancet       Date:  1974-02-02       Impact factor: 79.321

6.  Quantitative assay for plant viruses using serologically specific electron microscopy.

Authors:  K S Derrick
Journal:  Virology       Date:  1973-12       Impact factor: 3.616

7.  Simian virus SA11 and the related O agent.

Authors:  H H Malherbe; M Strickland-Cholmley
Journal:  Arch Gesamte Virusforsch       Date:  1967

8.  Plaque assay of neonatal calf diarrhea virus and the neutralizing antibody in human sera.

Authors:  S Matsuno; S Inouye; R Kono
Journal:  J Clin Microbiol       Date:  1977-01       Impact factor: 5.948

9.  Reoviruslike agent in stools: association with infantile diarrhea and development of serologic tests.

Authors:  A Z Kapikian; H W Kim; R G Wyatt; W J Rodriguez; S Ross; W L Cline; R H Parrott; R M Chanock
Journal:  Science       Date:  1974-09-20       Impact factor: 47.728

10.  In vitro cultivation in human fetal intestinal organ culture of a reovirus-like agent associated with nonbacterial gastroenteritis in infants and children.

Authors:  R G Wyatt; A Z Kapikian; T S Thornhill; M M Sereno; H W Kim; R M Chanock
Journal:  J Infect Dis       Date:  1974-11       Impact factor: 5.226

View more
  42 in total

1.  Serum albumin treatment to eliminate false-positive results with laboratory rodent specimens tested by rotazyme enzyme-linked immunosorbent assay.

Authors:  M N Jure; S S Morse; D M Stark
Journal:  J Clin Microbiol       Date:  1987-11       Impact factor: 5.948

2.  Evaluation of new commercial enzyme immunoassay for rotavirus detection.

Authors:  J L Cromien; C A Himmelreich; R I Glass; G A Storch
Journal:  J Clin Microbiol       Date:  1987-12       Impact factor: 5.948

3.  Multicentre evaluation of a new commercial latex agglutination test using a monoclonal antibody for rotavirus detection.

Authors:  E Kohli; P Pothier; F Denis; F Freymuth; A Goudeau
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-03       Impact factor: 3.267

4.  Comparison of a new rapid test (TestPack Rotavirus) with standard enzyme immunoassay and electron microscopy for the detection of rotavirus in symptomatic hospitalized children.

Authors:  R G Brooks; L Brown; R B Franklin
Journal:  J Clin Microbiol       Date:  1989-04       Impact factor: 5.948

5.  Comparison of nine commercial immunoassays for the detection of rotavirus in fecal specimens.

Authors:  P H Dennehy; D R Gauntlett; W E Tente
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

6.  Comparison of three enzyme immunoassays to tissue culture for the diagnosis of rotavirus gastroenteritis in infants and young children.

Authors:  C Christy; D Vosefski; H P Madore
Journal:  J Clin Microbiol       Date:  1990-06       Impact factor: 5.948

7.  Epidemiology of rotavirus electropherotypes determined by a simplified diagnostic technique with RNA analysis.

Authors:  K T Dolan; E M Twist; P Horton-Slight; C Forrer; L M Bell; S A Plotkin; H F Clark
Journal:  J Clin Microbiol       Date:  1985-05       Impact factor: 5.948

8.  Evaluation of four tests for detecting human rotavirus in feces.

Authors:  T Shinozaki; H Ushijima; T Tajima; B Kim; K Araki; R Fujii
Journal:  Eur J Pediatr       Date:  1985-01       Impact factor: 3.183

9.  Detection of group A rotavirus by reverse transcriptase and polymerase chain reaction in feces from children with acute gastroenteritis.

Authors:  M Husain; P Seth; S Broor
Journal:  Arch Virol       Date:  1995       Impact factor: 2.574

10.  Diagnosing norovirus-associated infectious intestinal disease using viral load.

Authors:  Gemma Phillips; Ben Lopman; Clarence C Tam; Miren Iturriza-Gomara; David Brown; Jim Gray
Journal:  BMC Infect Dis       Date:  2009-05-14       Impact factor: 3.090

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.