Comparison of a new rapid test (TestPack Rotavirus) with standard enzyme immunoassay and electron microscopy for the detection of rotavirus in symptomatic hospitalized children.

R G Brooks1, L Brown, R B Franklin.   

Abstract

We compared a new, rapid, qualitative test for rotavirus (TestPack Rotavirus; Abbott Laboratories, North Chicago, Ill.) with another enzyme immunoassay (Pathfinder Rotavirus; Kallestad Laboratories, Inc., Austin, Tex.) and electron microscopy to determine its clinical utility in a population of symptomatic hospitalized children. In the first part of the study, 100 frozen stool samples were tested. The results after resolution with a blocking reagent showed a sensitivity of only 50% and a specificity of 88% for TestPack Rotavirus. In the second part of the study, we tested TestPack Rotavirus on 100 fresh, unfrozen samples. The results (sensitivity/specificity) were as follows: TestPack Rotavirus, 95/90%; Pathfinder Rotavirus, 84/98%; direct electron microscopy, 63/100%. Although it was not as sensitive or specific as immune electron microscopy, TestPack Rotavirus was more sensitive than direct electron microscopy or Kallestad Pathfinder Rotavirus. TestPack Rotavirus represents a rapid, qualitative method for the detection of rotavirus in stools of symptomatic children.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2542368      PMCID: PMC267417          DOI: 10.1128/jcm.27.4.775-777.1989

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  19 in total

1.  Analysis of nonspecific reactions in enzyme-linked immunosorbent assay testing for human rotavirus.

Authors:  R H Yolken; P J Stopa
Journal:  J Clin Microbiol       Date:  1979-11       Impact factor: 5.948

2.  Detection of rotavirus with a new polyclonal antibody enzyme immunoassay (Rotazyme II) and a commercial latex agglutination test (Rotalex): comparison with a monoclonal antibody enzyme immunoassay.

Authors:  G V Doern; J E Herrmann; P Henderson; D Stobbs-Walro; D M Perron; N R Blacklow
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

3.  Ability of TESTPACK ROTAVIRUS enzyme immunoassay to diagnose rotavirus gastroenteritis.

Authors:  M Chernesky; S Castriciano; J Mahony; M Spiewak; L Schaefer
Journal:  J Clin Microbiol       Date:  1988-11       Impact factor: 5.948

4.  Virus particles in epithelial cells of duodenal mucosa from children with acute non-bacterial gastroenteritis.

Authors:  R F Bishop; G P Davidson; I H Holmes; B J Ruck
Journal:  Lancet       Date:  1973-12-08       Impact factor: 79.321

5.  Detection of human rotaviruses in fecal specimens by a commercial latex-agglutination test.

Authors:  G W Hammond; G S Ahluwalia; P R Hazelton
Journal:  J Infect Dis       Date:  1984-06       Impact factor: 5.226

6.  Comparison of an enzyme immunoassay with electron microscopic procedures for detecting rotavirus.

Authors:  A S Rubenstein; M F Miller
Journal:  J Clin Microbiol       Date:  1982-05       Impact factor: 5.948

7.  Comparative efficiency of commercial immunoassays for the diagnosis of rotavirus gastroenteritis during the course of infection.

Authors:  P G Miotti; J Eiden; R H Yolken
Journal:  J Clin Microbiol       Date:  1985-11       Impact factor: 5.948

8.  Detection of rotavirus in faeces by latex agglutination.

Authors:  T Sanekata; Y Yoshida; H Okada
Journal:  J Immunol Methods       Date:  1981       Impact factor: 2.303

9.  Comparison of immunosorbent electron microscopy, enzyme immunoassay and counterimmunoelectrophoresis for detection of human rotavirus in stools.

Authors:  G Obert; R Gloeckler; J Burckard; M H van Regenmortel
Journal:  J Virol Methods       Date:  1981-09       Impact factor: 2.014

10.  Comparison of direct electron microscopy, immune electron microscopy, and rotavirus enzyme-linked immunosorbent assay for detection of gastroenteritis viruses in children.

Authors:  C D Brandt; H W Kim; W J Rodriguez; L Thomas; R H Yolken; J O Arrobio; A Z Kapikian; R H Parrott; R M Chanock
Journal:  J Clin Microbiol       Date:  1981-05       Impact factor: 5.948

View more
  5 in total

1.  Occurrence of nonspecific reactions among stool specimens tested by the Abbott TestPack rotavirus enzyme immunoassay.

Authors:  S M Lipson; G P Leonardi; R J Salo; T E Schutzbank; M H Kaplan
Journal:  J Clin Microbiol       Date:  1990-06       Impact factor: 5.948

2.  A prospective evaluation of community acquired gastroenteritis in paediatric practices: impact and disease burden of rotavirus infection.

Authors:  M Frühwirth; W Karmaus; I Moll-Schüler; S Brösl; I Mutz
Journal:  Arch Dis Child       Date:  2001-05       Impact factor: 3.791

3.  Breastfeeding protects against acute gastroenteritis due to rotavirus in infants.

Authors:  Anita Plenge-Bönig; Nelís Soto-Ramírez; Wilfried Karmaus; Gudula Petersen; Susan Davis; Johannes Forster
Journal:  Eur J Pediatr       Date:  2010-07-09       Impact factor: 3.183

4.  Choice of reference assay for the detection of rotavirus in fecal specimens: electron microscopy versus enzyme immunoassay.

Authors:  P H Dennehy; D R Gauntlett; S E Spangenberger
Journal:  J Clin Microbiol       Date:  1990-06       Impact factor: 5.948

5.  Opportunities for rapid viral diagnosis.

Authors:  Terrance A Bruner; Daniel P Fedorko
Journal:  Clin Microbiol Newsl       Date:  2002-11-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.